Display The Master Freq Command Source; Display The Operation Command Source; User-Defined Value 2 Setting - Delta Electronics AC Motor Drive VFD-EL User Manual

Vfd-el multiple functions / micro type ac motor drive
Table of Contents

Advertisement

These parameters are used to determinate the frequency at stop:
When setting Pr.02.14 to 0: the initial frequency will be current frequency.
When setting Pr.02.14 to 1: the initial frequency will be 0.
When setting Pr.02.14 to 2: the initial frequency will be Pr.02.15.
02.16

Display the Master Freq Command Source

Settings
You can read the master frequency command source by this parameter.
Display Value
Bit
1
Bit0=1
2
Bit1=1
4
Bit2=1
02.17

Display the Operation Command Source

Settings
You can read the operation source by this parameter.
Display Value
1
2
4
8
02.18

User-defined Value 2 Setting

Settings
Revision August 2008, 2ELE, V1.02
Read Only
Master Freq Command Source by First Freq Source (Pr.02.00).
Master Freq Command Source by Second Freq Source (Pr.02.09).
Master Freq Command Source by Multi-input function
Read Only
Bit
Bit0=1
Operation Command Source by Digital Keypad
Bit1=1
Operation Command Source by RS485 communication
Bit2=1
Operation Command Source by External Terminal
Bit3=1
Operation Command Source by Multi-input function
0 to Pr.00.13
Chapter 4 Parameters|
Function
Function
Factory setting: ##
Factory setting: ##
Unit: 1
Factory Setting: 0
4-45