Chapter 4 Parameters|
Parameter
Explanation
Mid-Point Voltage
01.04
(Vmid)
Minimum Output
01.05
Frequency (Fmin)
Minimum Output
01.06
Voltage (Vmin)
Output Frequency
01.07
Upper Limit
Output Frequency
01.08
Lower Limit
01.09
Accel Time 1
01.10
Decel Time 1
01.11
Accel Time 2
01.12
Decel Time 2
01.13
Jog Acceleration
Time
01.14
Jog Deceleration
Time
01.15
Jog Frequency
Auto acceleration /
deceleration (refer
01.16
to Accel/Decel time
setting)
Acceleration S-
01.17
Curve
Deceleration S-
01.18
Curve
Accel/Decel Time
01.19
Unit
4-4
Settings
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.1 to 120.0%
0.0 to100.0 %
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.10 Hz to Fmax (Pr.01.00) Hz
0: Linear Accel/Decel
1: Auto Accel, Linear Decel
2: Linear Accel, Auto Decel
3: Auto Accel/Decel (Set by load)
4: Auto Accel/Decel (set by Accel/Decel
Time setting)
0.0 to 10.0 / 0.00 to 10.00 sec
0.0 to 10.0 / 0.00 to 10.00 sec
0: Unit: 0.1 sec
1: Unit: 0.01 sec
Factory
Setting
10.0
20.0
1.50
10.0
20.0
110.0
0.0
10.0
10.0
10.0
10.0
1.0
1.0
6.00
0
0.0
0.0
0