Password Set - Delta Electronics AC Motor Drive VFD-EL User Manual

Vfd-el multiple functions / micro type ac motor drive
Table of Contents

Advertisement

Password Set

00.09
Settings
Display
To set a password to protect your parameter settings.
If the display shows 0, no password is set or password has been correctly entered in Pr.00.08.
All parameters can then be changed, including Pr.00.09.
The first time you can set a password directly. After successful setting of password the display
will show 1.
Be sure to record the password for later use.
To cancel the parameter lock, set the parameter to 0 after inputting correct password into Pr.
00.08.
The password consists of min. 1 digits and max. 4 digits.
How to make the password valid again after decoding by Pr.00.08:
Method 1: Re-input original password into Pr.00.09 (Or you can enter a new password if you
Method 2: After rebooting, password function will be recovered.
Password Decode Flow Chart
Displays 0 when
entering correct
password into
Pr.00.08.
Revision August 2008, 2ELE, V1.02
0 to 9999
0
No password set or successful input in Pr. 00.08
1
Password has been set
want to use a changed or new one).
00.09
Correct Password
00.09
Displays 0 when
entering correct
password into
Pr.00.08.
00.08
Incorrect Password
END
3 chances to enter the correct
password.
1st time displays "1" if
password is incorrect.
2nd time displays "2", if
password is incorrect.
3rd time displays " code"
(blinking)
If the password was entered
incorrectly after three tries,
the keypad will be locked.
Turn the power OFF/ON to
re-enter the password.
Chapter 4 Parameters|
Factory Setting: 0
END
00.08
Unit: 1
4-29