Connection modules for VIBRONET MUX - VIB 8.31x
PARAMETER
Input
Pt100 temperature probe
Output
Digitalized current signal
Measurment range
-40C° ...+ 250°C
Sensitivity
0,385 Ohm/°C
Current output to sensor
< 2 mA
Voltage output to sensor
< 1 V
Balancing resistor
--
Operation temperature
Dimensions
46 x 50 x 2 mm
VIB 8.310 /
VIB 8.312
VIB 8.310 EX
Current / Voltage
0 ...20mA / -10...+10V
--
--
< 2.2 V (at connector, current module)
10 kOhm (Input resistance, voltage module)
-20C° ...+ 80°C (... +70°C with EX version)
Technical data
VIB 8.313 /
VIB 8.314 EX
VIB 8.313-1 EX
Inductive
CLD-type
proximity sensor
accelerometer
-
-
2 mA
--
< 4 mA
--
< 8 V
--
100 Ohm
-40C° ...+ 70°C
* only for installation in hazardous areas