Setup Screens - Graco Reactor 3 E-20 Elite Operation

Proportioning system
Hide thumbs Also See for Reactor 3 E-20 Elite:
Table of Contents

Advertisement

Advance Display Module (ADM)
Setup

Setup Screens

Setup
Screens
Screens
Use the Setup screens screens to edit settings
for the Reactor system.
Pressure/Flow
Pressure/Flow
Pressure/Flow
Use the Pressure/Flow screen to set pressure
monitoring settings for the Reactor system.
Setting
Setting
Setting
Description
Description
Description
Enable Auto
This feature monitors the pressure
Pressure Balance
imbalance while material is flowing
and adds temperature offsets to the
setpoints to minimize the pressure
imbalance.
Tap the checkbox to enable/disable
Auto Pressure Balance. Tap
the number value to adjust the
temperature offset limit allowed
using Auto Pressure Balance.
NOTE:
NOTE:
NOTE: This feature is only enabled
on Pro and Elite models.
Enable Pressure
Tap the checkbox to enable/disable
Imbalance Alarms
Pressure Imbalance Alarms. Tap the
number value to adjust the alarm
threshold.
NOTE: Pressure imbalance alarms are
NOTE:
NOTE:
automatically enables if flow meters
are enabled.
Enable Pressure
Tap the checkbox to enable/disable
Imbalance
Pressure Imbalance Deviations. Tap
Deviations
the number value to adjust the
deviation threshold.
Enable Reactor
Tap the checkbox to enable/disable
Smart Control
Reactor Smart Control. This feature
does the following:
• Slows down the proportioner pump
if inlet pressure is low. This is
done to allow the transfer pumps
to keep up and avoid off-ratio
conditions.
• Controls the output pressure to the
average of the A and B pressure
sensors (instead of the max).
Enable Flow
Tap the checkbox to enable/disable
Meters
flow meters.
Enable Flow Meter
Tap the checkbox to enable/disable
Alarms
flow meter alarms. Tap the number
value to adjust the alarm threshold.
NOTE: Flow meter alarms are only
NOTE:
NOTE:
available when flow meters are
installed.
Flow Meter A
Tap the number value to enter the
K-Factor
K-Factor for the A side flow meter.
NOTE: The K-Factor is noted on the
NOTE:
NOTE:
meter label.
Flow Meter B
Tap the number value to enter the
K-Factor
K-Factor for the B side flow meter.
NOTE:
NOTE:
NOTE: The K-Factor is noted on the
meter label.
44
Heat
Heat
Heat
Use the Heat screen to calibrate hose heat and
set the hose control mode.
To calibrate the system, see the
Calibration, page
36.
Setting
Description
Description
Description
Setting
Setting
Hose Control
Tap to select hose control mode.
Mode
FTS: control to target temperature
FTS:
FTS:
using an FTS (fluid temperature
sensor) on each side of the
hose. Calibration is required
to use FTS control mode. See
Calibration Procedure, page
Resistance:
Resistance: control to target
Resistance:
temperature using the resistance of
the heater element (changes with
temperature). Calibration is required
to use Resistance control mode. See
Calibration Procedure, page
Manual:
Manual:
Manual:
current (amps) to heat the hose.
Manual control mode has no
pre-programmed control and is
designed to be used for a limited
amount of time until a proper
calibration can be performed or FTS
issues can be resolved.
NOTE: When manual hose mode is
NOTE:
NOTE:
enabled, the manual hose mode
advisory (EVCH) will appear.
Hose A Calibration
Resistance value determined during
Factor
the calibration process for the A side
hose.
Hose B Calibration
Resistance value determined during
Factor
the calibration process for the B side
hose.
Last Calibration
Date/time of last successful
Date
calibration.
36.
36.
control to target