Home Screen - Graco Reactor 3 E-20 Elite Operation

Proportioning system
Hide thumbs Also See for Reactor 3 E-20 Elite:
Table of Contents

Advertisement

Home

Home Screen

Home
Screen
Screen
Use the Home screen to control the Reactor
system operation functions.
Temperature
Temperature
Temperature Control
Control Panel
Control
The Temperature Control panel contains
controls for Hose heat and A and B-side Primary
heaters.
Icon
Icon
Icon
Name
Name
Name
Primary
Heater A
On/Off
Primary
Heater B
On/Off
Hose Heat
On/Off
A (ISO)
Tempera-
ture Set-
point
B (RES)
Tempera-
ture Set-
point
Hose
Current
Setpoint
Reset Auto
Pressure
Balance
Tempera-
ture Offsets
3A8500A
Panel
Panel
Description
Description
Description
Tap to toggle the A primary heater
state.
Tap to toggle the B primary heater
state.
Tap to toggle the hose heat state.
Tap +/– to adjust the setpoint by
one degree. Press and hold +/- to
rapidly adjust the setpoint. Tap the
number to open a pop-up and type
in the setpoint directly.
Tap +/– to adjust the setpoint by
one degree. Press and hold +/- to
rapidly adjust the setpoint. Tap the
number to open a pop-up and type
in the setpoint directly
Tap +/– to adjust the setpoint by
one amp. Press and hold +/– to
rapidly adjust the setpoint. Tap the
number to open a pop-up and type
in the setpoint directly.
NOTE: The Hose Current Setpoint
NOTE:
NOTE:
button is only displayed if the Hose
Control Mode is set to Manual in
the
Setup, page 44
settings.
Tap to reset the Auto Pressure
Balance temperature offset values
(to the left and right of this button).
Advance Display Module (ADM)
A A A and
and B B B side
and
side Supply
side
Supply Control
Supply
The A and B Supply Control panels display the
remaining material supply for A and B side
materials, and contains controls for electric
transfer pumps (if applicable).
Icon
Name
Icon
Icon
Name
Name
Electric
Transfer
Pump A
On/Off
Electric
Transfer
Pump B
On/Off
A (ISO)
Transfer
Pump Jog
Level
B (RES)
Transfer
Pump Jog
Level
Control Panels
Control
Panels
Panels
Description
Description
Description
Press to toggle the A electric
transfer pump state.
NOTE: This button is only
NOTE:
NOTE:
displayed if an electric transfer
pump is installed and the
proportioner pump state is off.
The electric transfer pumps are
automatically turned on any
time the proportioner pump is
turned on.
Press to toggle the B electric
transfer pump state.
NOTE:
NOTE: This button is only
NOTE:
displayed if an electric transfer
pump is installed and the
proportioner pump state is off.
The electric transfer pumps are
automatically turned on any
time the proportioner pump is
turned on.
Tap +/– or the displayed jog
level number (i.e. J10) to set
the A-side transfer pump jog
level.
NOTE:
NOTE: Jog levels are between 1
NOTE:
and 20.
Jog Mode, page
31.
Tap +/– or the displayed jog
level number (i.e. J10) to set
the B-side transfer pump jog
level.
NOTE:
NOTE: Jog levels are between 1
NOTE:
and 20.
Jog Mode, page
31.
41