Spec Sheet - Hussmann DSF Installation And Operation Manual

Open fish service case
Table of Contents

Advertisement

Spec Sheet

REFRIGERATION DATA:
CASE LENGTH
CASE USAGE
2,'3',4',5',6'
FRESH SEAFOOD
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) BTU'S INCLUDE NO CANOPY LIGHTS AND NO SHELF LIGHTS
2) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
3) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
4) THE PRINCIPAL COOLING EFFECT IN FISH CASES IS ACCOMPLISHED WITH A TRADITIONAL ICE BED. THE
REFRIGERATION PRESERVES THE ICE AND MAINTAINS A COLD PROTECTIVE LAYER OVER THE PRODUCT.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
REFRIGERATION DATA CONTINUED:
ELEC. THERMOSTAT / AIR SENSOR
SETTINGS
CUT IN
CUT OUT
USAGE
(ºF)
(ºF)
33
30
FRESH SEAFOOD
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
EVAPORATOR FANS
CASE
LENGTH *
# OF
BLADE
EVAP
DIA. (IN.)
FANS
2'
1
8
3'
1
8
4'
1
8
5'
2
8
6'
2
8
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CANOPY LIGHTS
CASE
H.O. LED
LENGTH *
AMPS
WATTS
2'
N/A
N/A
3'
N/A
N/A
4'
N/A
N/A
5'
N/A
N/A
6'
N/A
N/A
SERVICE SEAFOOD
HUSSMANN - DSF (CHINO)
CAPACITY ***
TEMPERATURE (ºF)
(BTU/HR/FT)
RATING CONDITION
EVAPORATOR
NSF 7
NSF 7
AHRI 1200
AHRI 1200
400
400
24
24
DEFROST
DEFROST
TIME
FREQUENCY
TYPE
(MIN)
(#/DAY)
OFF TIME
46
3
HUMIDITY FANS
(OPTIONAL)
# OF
BLADE
AMPS
WATTS
HUMIDITY
PITCH (°)
FANS
10
0.6
50
1
10
0.6
50
1
10
0.6
50
1
10
0.6
50
1
10
1.2
100
1
MAX. H.O. LED
OPTIONAL SHELF
LOAD
AMPS
WATTS
AMPS
WATTS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
VELOCITY
(FT/MIN)
DISCHARGE
AIR ** (°F)
NSF 7
NSF 7
30~32
350~500
TERM.
DEFROST
TEMP
DRIP
WATER
(°F)
TIME
COIL
(LBS/DAY/FT)
ONLY
48
N/A
1.1
CANOPY
OPTIONAL LED
LIGHTS LED
SHELF LIGHTS
OPTIONAL
AMPS WATTS AMPS
WATTS
AMPS WATTS
0.1
8
N/A
N/A
N/A
0.1
8
N/A
N/A
N/A
0.1
8
N/A
N/A
N/A
0.1
8
N/A
N/A
N/A
0.1
8
N/A
N/A
N/A
CASE ENERGY USAGE DATA:
CASE LENGTH /
TDA/V (ft
WEDGES
3
(ft
wedges)
4.09
3',4',5',6',8',10',12'
22.5° IS
49.08
22.5° OS
45° OS
20.3682
45° IS
90° OS
8
REFG.
CASE
LENGTH
CHRG.
(R404A)
*
(LBS)
2'
3'
4'
5'
6'
END PANEL WIDTH KEY
# OF
END PNL
END
WIDTH
PNLS
1
1.125
2
1.125
ANTI-SWEAT
MAX. LED LOAD
(W/ ALL OPTIONS)
HEATERS
AMPS
WATTS
AMPS
WATTS
N/A
N/A
N/A
0.1
N/A
N/A
N/A
0.1
N/A
N/A
N/A
0.2
N/A
N/A
N/A
0.2
N/A
N/A
N/A
0.3
ACTUAL CDEC
MAX ALLOWABLE
2
/ft)
(KWh/day/ft)
CDEC (KWh/Day/ft)
(KWh/day wedges)
(KWh/day wedges)
1.28
3.02
14.62
35.57
0
1.34
3.18
5.19
16.62
0
1.34
3.18
0
1.34
3.18
REVISION DATE
09/01/17
EST.
20°F GLYCOL
6° RISE
GPM
PSI
0.3
0.3
0.1
0.5
0.4
0.5
0.7
0.6
1.1
0.9
0.7
1.9
1.1
0.8
0.4
TOTAL ADDED
LENGTH (IN.)
(IN.)
1.125
2.25
CONVENIENCE
OUTLETS (OPTIONAL)
#
VOLTS AMPS
OUTLETS
11
1
115
15
17
1
115
15
23
1
115
15
29
1
115
15
34
1
115
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

DsfiDsfmDsfnDsfn-ep

Table of Contents