Step 4. Positioning, Leveling, and Securing
the Fireplace
The diagram below shows how to properly position, level,
and secure the fireplace.
Figure 27. Proper Positioning, Leveling, and
Securing of a Fireplace
• Place the fireplace into position.
• Level the fireplace from side to side and from front to
back.
• Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
• Secure the fireplace to the framing by nailing or screw-
ing.
• Holes are provided in the base pan for securing the unit
to the floor.
29
NAILING TABS
(BOTH SIDES)
Heat & Glo • PIER/ST/L&RCOR-HVB-CE • 2068-900 Rev. o • 3/13

Step 5. The Gas Control System

wARNING: THIS UNIT IS NOT FOR USE wITH
!
SOLID FUEL.
Flame Sensor Rod
Figure 28. Gas Control System
Standing Pilot Ignition System
This system includes millivolt control valve, Standing Pilot,
thermopile/thermocouple flame sensor, and piezo ignitor.
wARNING: 230 VAC MUST NEVER BE CON-
!
NECTED TO A CONTROL VALVE IN A MIL-
LIVOLT SySTEM.