Batch Data Insertion - Mitsubishi Electric MELSEC-L Series User Manual

Hide thumbs Also See for MELSEC-L Series:
Table of Contents

Advertisement

8.4.6

Batch data insertion

In the data list, a block of data can be inserted all at once. Data are entered in order from the highest numbered blank
line on the "Data" setting screen.
(1) Operating procedure
In the right-click menu on the "Data" setting screen, select "Batch data insertion".
(2) Setting screen
(3) Setting items
Item
Device
Set a data sampling device.
Head
Specify the head device number.
Last
The last device number calculated from the data type and size is displayed.
Data type
Select a data type of the target data.
Size
Specify the size when the data type is "String" or "Raw".
Clicking the
Output Format
float)" dialog box. Select the type of the format for data output to files.
Continuous setting
Specify the total number of device data and interval.
Total number
Specify the total number of data to be entered all at once.
Interval
Specify the interval of the data to be entered all at once.
Description
button on the right of "Output Format" displays the "Output format (integer/
CHAPTER 8 HOW TO USE THE CONFIGURATION TOOL
• Bit
• Word [signed]
• Double word [signed]
• Word [unsigned]
• Double word [unsigned]
• FLOAT [single precision]
• FLOAT [double precision]
• String
• Raw
1 to 256 bytes
• Decimal format
• Hexadecimal format
• Exponential format (Number of
digits: 0 to 14)
2 to 128 points
1 to 2108416 points
Setting range
-
-
-
-