Furuno FSV-30 Operator's Manual page 38

Color scanning sonar
Hide thumbs Also See for FSV-30:
Table of Contents

Advertisement

2. HORIZONTAL MODE
Note: Wide tilt angle is also available, from the SYSTEM menu. For details,
contact your dealer or refer to installation manual.
Range
60, 100, 150
200
300, 400
500, 600
800
1000
more than 1200
*: The period for the horizontal mode. In the V1/V2 mode, every 2
transmissions for 60 to 200 m range and every transmission for 300 m
range and greater.
For example, when the [RANGE] control, [TILT] control and [AUTO TILT] key are
set to 200 m, 8 and width (1) respectively, the tilt angle changes at each
transmission as follows:
8
9
10
Note: The [AUTO TILT] key is inoperative when the target lock function is active
or is made active. Once the target lock is turned off auto tilt operation is
resumed.
2-8
OFF
2 - 10
Automatic tilt range (wide) with AUTO TILT key
Width (1)
10
As above
As above
As above
As above
8
As above
6
4
2
9
8
7
6
7
Auto tilt concept
[
[
4 - 16
6 - 20
Width (2)
Width (3)
16
20
As above
As above
As above
12
16
8
12
4
6
...
8
Tilt angle setting
(Wide)
Period*
Every 4 trans.
Every 3 trans.
Every 2 trans.
As above
As above
As above
As above

Hide quick links: