13

Height of the needles

.11
Requirement
When the needles are extended, there should be a 4 mm clearance between the needle
points and the front edge of the loading table 1.
Fig. 13 - 27
Detach the cover plate of loading table
Extend the needles.
Adjust needles
2
1 (screws 2) in accordance with the requirement.
The cover plate remains detached for further adjustments.
1
1.
Adjustment