1
Checking the calibration
.03
●
Carry out the calibration as described in Chapter
●
Call up the service menu.
●
Call up the sensor function.
●
Attach the calibration weight (
ments have stopped.
●
Record the measured value shown in box
●
Repeat the measurements four more times and record each value in the calibration certi-
fi cate. The measured value must always be within the range of 500 cN +/- 30 cN.
●
If there are deviations, the characteristic thread strength curve must be re-recorded in ac-
cordance with Chapter 1.02.05 Characteristic thread strength curve.
●
Quit the menu.
●
Call up the mode selection function.
(calibration result)
1.02 Calibration procedure.
1
500 cN) to the thread and wait until the pendulum move-
1 in the calibration certifi cate.
Calibration
11