Checking The Calibration (Calibration Result) - Pfaff POWERline 3741 Manual

Doku-seam-system
Hide thumbs Also See for POWERline 3741:
Table of Contents

Advertisement

1
Checking the calibration
.03
Carry out the calibration as described in Chapter
Call up the service menu.
Call up the sensor function.
Attach the calibration weight (
ments have stopped.
Record the measured value shown in box
Repeat the measurements four more times and record each value in the calibration certi-
fi cate. The measured value must always be within the range of 500 cN +/- 30 cN.
If there are deviations, the characteristic thread strength curve must be re-recorded in ac-
cordance with Chapter 1.02.05 Characteristic thread strength curve.
Quit the menu.
Call up the mode selection function.
(calibration result)
1.02 Calibration procedure.
1
500 cN) to the thread and wait until the pendulum move-
1 in the calibration certifi cate.
Calibration
11