Check The Zero Position Of The Monitor Power Signal - Pfaff POWERline 3741 Manual

Doku-seam-system
Hide thumbs Also See for POWERline 3741:
Table of Contents

Advertisement

Switch on the monitor with function
Carry out a test seam.
Check, whether the trigger signals with the largest hook loop and in t.d.c. take-up lever
are both in the maximum range of the thread strength signal.
If necessary alter the value for parameter
accordingly.
If necessary alter the value for parameter
accordingly.
Carry out another test seam and check the altered value.
If necessary repeat the procedure until the setting for the trigger signals is correct.
Enter the values for the speed (
calibration certifi cate.
Call up the mode selection function.
1

Check the zero position of the monitor power signal

.02.03
(Item 3 of the calibration certifi cate)
Call up the "tools" function.
Call up the menu for adjusting the parameter values.
Call up parameter
Check whether the value "
Call up the mode selection function.
1.
500 min-1) and for the parameters 2011 and 2013 in the
2010.
244" is set. If necessary enter this value.
Industrial
2011 (largest hook loop, standard value: "344")
2013 (t.d.c. take-up lever, standard value: "74")
Calibration
7