Switch on the monitor with function
●
Carry out a test seam.
●
Check, whether the trigger signals with the largest hook loop and in t.d.c. take-up lever
are both in the maximum range of the thread strength signal.
●
If necessary alter the value for parameter
accordingly.
●
If necessary alter the value for parameter
accordingly.
●
Carry out another test seam and check the altered value.
●
If necessary repeat the procedure until the setting for the trigger signals is correct.
●
Enter the values for the speed (
calibration certifi cate.
●
Call up the mode selection function.
1
Check the zero position of the monitor power signal
.02.03
(Item 3 of the calibration certifi cate)
●
Call up the "tools" function.
●
Call up the menu for adjusting the parameter values.
●
Call up parameter
●
Check whether the value "
●
Call up the mode selection function.
1.
500 min-1) and for the parameters 2011 and 2013 in the
2010.
244" is set. If necessary enter this value.
Industrial
2011 (largest hook loop, standard value: "344")
2013 (t.d.c. take-up lever, standard value: "74")
Calibration
7