Input
Soft top limit
The limit value is entered in sector 4 In the docu-seam area this value may be exceeded a
few times. The number of tolerance stitches is entered in sector 7.
Setpoint
(only on the PFAFF 3745 PREMIUM)
The Setpoint is entered in sector 5.
Soft bottom limit
The limit value is entered in sector 6. In the docu-seam area it is possible to drop below this
level a few times. The number of tolerance stitches is entered in sector 7.
Tolerance stitches
The number of tolerance stitches is entered in sector 7. The number of tolerance stitches is
used to defi ne how often the thread strength within the docu-seam area may exceed or drop
below the soft limits.
Thread tension control
(only on the PFAFF 3745 PREMIUM)
Pressing the button 8 deactivates the function "Thread tension control" during sewing,
button 9 reactivates the function.
Pressing button 10 activates the function "Thread tension control" at the end of the
range only.
Conclude the input
The input is concluded by taking over the selection and the entered values.
Stop the input
The input is concluded without taking over the selection and the entered values.