Field Service Ver. 1.0 Nov. 2008
19.1.2
White lines in CD, white bands in CD, colored lines in CD, and colored
bands in CD
A. Typical faulty images
White lines in CD
4036fs4025c0
B. Troubleshooting procedure
Step
Section
1
2
Imaging
3
cartridge
4
5
Toner cartridge
6
PH unit
2nd transfer
7
roller
8
Media path
9
Fuser unit
10
White bands in CD
4036fs4026c0
Check item
Are there scratches or lines evi-
dent on the photo conductor sur-
face?
Is the outside dirty?
Is the connector or contact termi-
nal of the imaging cartridge con-
nected properly?
Is the transfer belt dirty or
scratched?
Is the developing bias contact ter-
minal in good contact?
Is the connector or contact termi-
nal of the PH unit connected
properly?
Is the 2nd transfer roller dirty or
scratched?
Is there a foreign object in the
media path?
Is the fusing entrance guide plate
dirty or scratched?
Have steps 1 to 9 eliminated the
problem?
19. Image quality problems
Colored lines in CD
Colored bands in CD
4036fs4027c0
Result
YES
Replace the imaging cartridge.
YES
Clean.
NO
Clean the contact terminal.
Wipe the surface clean of dirt with
a soft cloth.
YES
Replace the scratched transfer
belt with a new imaging cartridge.
Clean the contact terminal or
NO
check the terminal position.
Clean the contact terminal or
NO
reconnect the connector.
YES
Replace the 2nd transfer roller.
YES
Remove the foreign object.
YES
Clean.
NO
Replace the DC power supply.
4036fs4028c0