A. Typical faulty images
B. Troubleshooting procedure
Step
Section
Imaging
1
cartridge
2
PH unit
IDC sensor
3
board
4
4036fs4048c0
Check item
Is the outside dirty?
Is the window surface dirty?
Is the sensor dirty?
Have steps 1 to 3 eliminated the
problem?
19. Image quality problems
4036fs4049c0
Result
Action
YES
Clean.
YES
Clean.
YES
Clean.
Replace the toner cartridge.
→ Replace the PH unit.
NO
→ Replace the IDC sensor board.
→ Replace the high voltage unit.
117