SiUS042113E

4. Troubleshooting

4.1

Error Codes and Description

System
Indoor
Unit
Outdoor
Unit
: Displayed only when system-down occurs.
Part 6 Service Diagnosis
Error
Codes
Normal
00
U0
Refrigerant shortage
U2
Low-voltage detection or over-voltage detection
Signal transmission error (between indoor unit and outdoor
U4
unit)
UA
Unspecified voltage (between indoor unit and outdoor unit)
Indoor unit PCB abnormality
A1
A5
Freeze-up protection control/heating peak-cut control
A6
Fan motor (DC motor) or related abnormality
Indoor heat exchanger thermistor or related abnormality
C4
Room temperature thermistor or related abnormality
C9
CC
Humidity sensor abnormality
E1
Outdoor unit PCB abnormality
E3
Actuation of high pressure switch
OL activation (compressor overload)
E5
E6
Compressor lock
E7
DC fan lock
E8
Input overcurrent detection
Four way valve abnormality
EA
F3
Discharge pipe temperature control
F6
High pressure control in cooling
F8
System shutdown due to compressor internal temperature
abnormality
H0
Compressor system sensor abnormality
Position sensor abnormality
H6
DC voltage/current sensor abnormality
H8
H9
Outdoor temperature thermistor or related abnormality
J3
Discharge pipe thermistor or related abnormality
J6
Outdoor heat exchanger thermistor or related abnormality
Liquid pipe thermistor or related abnormality
J8
L3
Electrical box temperature rise
L4
Radiation fin temperature rise
Output overcurrent detection
L5
Radiation fin thermistor or related abnormality
P4
Description

Troubleshooting

Reference
Page
97
99
101
103
90
91
93
95
95
96
104
105
106
109
110
111
113
115
117
119
120
121
124
126
126
126
126
128
129
131
126
89

Hide quick links: