Outdoor Unit; 09/12 Class - Daikin FTXM-V Series Service Manual

Table of Contents

Advertisement

Outdoor Unit

2. Outdoor Unit
2.1

09/12 class

Main PCB (A1P)
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
HL1
S
FU1
V1
LEDA
S80
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
20
S20
Connector for electronic expansion valve coil
S40
Connector for overload protector
S70
Connector for DC fan motor
S80
Connector for four way valve
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge
pipe temperature)
S97
Connector for liquid pipe thermistor
HL1, HN1, S
Wire harness for terminal strip
E1, E2
Wire harness for earth/ground wire
U, V, W
Wire harness for compressor
FU1, FU2
Fuse (3.15 A, 250 V)
FU3
Fuse (30 A, 250 V)
LEDA
LED for service monitor (green)
V1, V2, V3
Varistor
J4
Jumper for facility setting
Refer to page 153 for details.
J9
Jumper for drain pan heater
Refer to page 154 for details.
HN1
V3
FU3
V2
S20
S70
S40
E1
E2
FU2
S90
J9
J4
S97
Part 3 Printed Circuit Board Connector Wiring Diagram
SiUS042113E
W V U
2P628602-1

Hide quick links: