SiUS042113E
3.4.4 3-Minute Standby
Turning on the compressor is prohibited for 3 minutes after turning off.
The function is not used when defrosting.
3.4.5 Compressor Protection Function
When turning the compressor from OFF to ON, the upper limit of frequency is set as follows. (The
function is not used when defrosting.)
A (Hz)
B (Hz)
C (Hz)
D (Hz)
E (Hz)
F (sec)
G (sec)
H (sec)
J (sec)
K (sec)
Part 4 Functions and Control
(Hz)
Frequency
E
D
C
B
A
F
09/12 class
Cooling
Heating
36
36
52
52
68
68
80
80
110
110
120
120
120
120
480
480
180
180
600
600
G
H
J
18/24 class
Cooling
Heating
48
48
48
48
62
62
80
80
100
100
800
800
300
300
470
470
Control Specification
(sec.)
Time
K
(R23251)