Main Functions
3. Airflow direction in 2-area INTELLIGENT EYE operation
 Detection method: The opposite area of detected area is set as the target direction.
1. Human detection signal ON in both areas A and B: Shift the airflow direction to area B (left side)
2. Human detection signal ON in area A: Shift the airflow direction to area B (left side)
3. Human detection signal ON in area B: Shift the airflow direction to area A (right side)
4. Human detection signal OFF in both areas A and B: No change
 When the human detection signal is OFF for 20 minutes in both areas A and B, the unit starts
energy saving operation.
Note(s)
For dry operation, the temperature cannot be set with a remote controller, but the target
temperature is shifted internally.
Comfort/Focus
Depending on the settings, you can select the airflow control whether blowing directly toward
Airflow
(Focus) or away from (Comfort) the people.
[Example]
Note(s)
Notes on energy saving operation
 If no presence detected in the room for 20 minutes, the energy saving operation will start, and
 This operation changes the temperature by –3.6°F (–2.0°C) in HEAT / +3.6°F (+2.0°C) in COOL
 This operation decreases the airflow rate slightly in FAN operation only.
38
Left
A person is detected in
area 1.
Area 1
Area 2
Area 1
Area 2
the INTELLIGENT EYE lamp goes off.
If human movement is detected again, the INTELLIGENT EYE lamp lights up and energy
saving operation terminates.
/ +3.6°F (+2.0°C) in DRY operation from the set temperature.
When the room temperature exceeds 86°F (30.0°C), the operation changes the temperature by
+1.8°F (+1.0°C) in COOL / +1.8°F (+1.0°C) in DRY operation from the set temperature.
Indoor unit
Human
Area A
Area B
A person is detected in
People are detected in
area 2.
both areas.
Area 1
Area 2
Area 1
When INTELLIGENT EYE
operation is used, the unit will
not blow air directly at people
Area 1
Area 2
(only in their general direction).
Wall
Top view
Right
(R3853)
No people are detected in
the areas.
Area 2
The air conditioner will switch
to energy-saving mode after
20 minutes.
Part 4 Functions and Control