Daikin FTXM-V Series Service Manual page 45

Table of Contents

Advertisement

SiUS042113E
Note(s)
For dry operation, the temperature cannot be set with a remote controller, but the target
temperature is shifted internally.
Notes on Energy saving operation
 If no presence detected in the room for 20 minutes, the energy saving operation will start, and
 This operation changes the temperature by –3.6°F (–2.0°C) in HEAT / +3.6°F (+2.0°C) in COOL
 This operation decreases the airflow rate slightly in FAN operation only.
Notes on INTELLIGENT EYE operation
 Application range is as follows.
 The air conditioner may switch to the energy-saving operation even if there are people in the
 The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off
 The sensor may not detect moving objects further than 23ft (7m) away. (Please see the
 Sensor detection sensitivity changes according to the indoor unit location, the speed of
 NIGHT SET mode will not switch on during use of INTELLIGENT EYE operation.
Part 4 Functions and Control
the INTELLIGENT EYE lamp goes off.
If human movement is detected again, the INTELLIGENT EYE lamp lights up and energy
saving operation terminates.
/ +3.6°F (+2.0°C) in DRY operation from the set temperature.
When the room temperature exceeds 86°F (30.0°C), the operation changes the temperature by
+1.8°F (+1.0°C) in COOL / +1.8°F (+1.0°C) in DRY operation from the set temperature.
Vertical angle 90°
(Side view)
areas.
This may occur depending on the clothes the people are wearing, if there is no movement of the
people in the areas.
of mirrors as passers-by.
application range)
passers-by, temperature range, etc.
Horizontal
angle 110°
55° 55°
(Top view)
90°
Main Functions