Thermostat Control - Daikin FTXM-V Series Service Manual

Table of Contents

Advertisement

Main Functions
1.8

Thermostat Control

Outline
Thermostat control is based on the difference between the room thermistor temperature and the
target temperature.
Details
Thermostat OFF Conditions
 The temperature difference is in the zone A.
Thermostat ON Conditions
 The temperature difference returns to the zone C after being in the zone A.
 The system resumes from defrost control in any zones except A.
 The operation turns on in any zones except A.
 The monitoring time has passed while the temperature difference is in the zone B.
Cooling
Heating
Reference
Refer to Temperature Control on page 24 for details.
34
(Cooling: 10 minutes, Heating: 10 seconds)
Zone C
Zone C
–1.0°C (–1.8°F)
Zone B
Zone B
–2.0°C (–3.6°F)
Zone A
Zone A
Zone A
Zone A
2.0°C (3.6°F)
Zone B
Zone B
1.5°C (2.7°F)
Zone C
Zone C
Room thermistor temperature – target temperature
ON
ON
–0.5°C (–0.9°F)
–1.5°C (–2.7°F)
OFF
OFF
Room thermistor temperature – target temperature
OFF
OFF
2.0°C (3.6°F)
1.0°C (1.8°F)
0.5°C (0.9°F)
ON
ON
SiUS042113E
(R24031)
(R24033)
Part 4 Functions and Control