Clkclearmessageonarrival(); Fins Message Reception Notification Clear; Clkgetlasterror(); Detailed Error Information Acquire - Omron SYSMAC 3G8F7-CLK12-E Operation Manual

Controller link support boards for pci bus
Table of Contents

Advertisement

Library Functions

4-1-11 ClkClearMessageOnArrival()

Function
Call Format
Arguments
Return Value

4-1-12 ClkGetLastError()

Function
Call Format
Arguments
Return Value
Description

FINS Message Reception Notification Clear

Clears windows message notification when a FINS message is received.
INT ClkClearMessageOnArrival(PCLKHANDLE hCLK);
Type
PCLKHANDLE
CLK_SUCCESS is returned if the function ends normally.
CLK_ERROR is returned if the function ends in an error. Detailed error informa-
tion can be obtained using ClkGetLastError().
Gets detailed error information generated when a Controller Link library function
is used.
INT ClkGetLastError(PCLKHANDLE hCLK);
Type
PCLKHANDLE
Detailed error information is returned if the function ends normally.
CLK_ERROR is returned if the function ends in an error.
Refer to 4-3 Detailed Error Information for details on the return value.
Variable name
hCLK
The CLK handle obtained with
ClkOpen()

Detailed Error Information Acquire

Variable name
hCLK
The CLK handle obtained with
ClkOpen()
Section
4-1
Description
Description
55

Advertisement