Error Codes - Omron SYSMAC 3G8F7-CLK12-E Operation Manual

Controller link support boards for pci bus
Table of Contents

Advertisement

Error Log
Error
Error
Contents
Contents
code
code
0003
CPU Unit RAM error
Hex
0004
CPU Bus Unit ID number error
Hex
0005
Unit number error
Hex
0006
CPU error
Hex
000E
I/O bus error
Hex
000F
CPU Unit initialization error
Hex
0010
System capacity exceeded
Hex
0011
CPU Unit initialization timeout
Hex
0012
CPU Unit memory error
Hex
0013
CPU Unit write-protected
Hex
134
Detail code
1st byte
2nd byte
01 Hex:
00 Hex
Cyclic
02 Hex:
Event
04 Hex:
CPU bus
link
00 Hex
00 Hex
Unit set
CPU Unit
value
detected
value
Bit 11: Unit missing in
registered I/O tables
Bit 12: Hard test number
detected
Bit 13: Illegal number
detected
Bit 14: Unit number
duplicated
00 Hex
00 Hex
01 Hex:
01 Hex:
Read error
Data link
02 Hex:
tables
Write error
02 Hex:
Network
parameters
03 Hex:
03 H
Routing
tables
04 Hex:
System
setup
Correction
Correction
Check the environment settings.
Check the I/O tables.
Check the unit number settings
and recreate the I/O tables.
Check the unit number settings
and recreate the I/O tables.
Check the environment settings.
Check the environment settings.
Check the environment settings.
Check the relevant settings.
Release write protection for the
CPU Unit.
Section
9-3
Recorded
Recorded
in
in
EEPROM
EEPROM
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes