Download Print this page

Specifications - YASKAWA A1000 Installation Manual

Motor pg feedback line driver interface
Hide thumbs Also See for A1000:

Advertisement

8 Specifications

8
Specifications
Items
Model
Compatible
Pulse Generators
PG Wiring Length
PG Power Supply
Compatible Control
Modes
Maximum Input
Frequency
Pulse Monitor Output
PG Disconnect
Detection
Ambient Temperature
Humidity
Storage Temperature
Area of Use
Altitude
30
Table 8 Option Specifications
PG-X3
Line driver
Single-channel (A pulse), two-channel (A, B pulse) or three-channel (A, B, Z (R)
pulse)
100 m (328 ft.) maximum
Output voltage: 12 V ± 5% or 5.5 V ± 5%
Max. Output Current: 200 mA
V/f with PG, Closed Loop Vector, Closed Loop Vector for PM motors
300 kHz
Monitor for A channel, B channel, and Z pulse output
Matches RS-422 level
Software and hardware detection
-10 °C to +50 °C (14 °F to 122 °F)
95% RH or lower with no condensation
-20 °C to +60 °C (-4 °F to 140 °F) allowed for short-term transport of the product
Indoor (free of corrosive gas, airborne particles, etc.)
1000 m (3280 ft.) or lower
YASKAWA ELECTRIC TOBP C730600 37B 1000-Series Option PG-X3 Installation Manual
Specifications

Advertisement

loading

This manual is also suitable for:

L1000a