When disposing of the Sensor, treat it as industrial waste.
Mounting Diagram
Use a mounting torque of
0.5 N·m max.
Oil Resistance
• The Sensor has passed oil resistance testing for the oils listed in the
following table. Use this table as a guide when considering
lubricants and cutting oils.
Test oil type
Product name
Lubricants
Velocity Oil No. 3
Non-water-solu-
Yushiron Oil No.2 AC
ble cutting oils
Yushiroken EC50T3
Yushiroken EC50T5
Yushiroken S46D
Yushiroken S50N
Yushiron Lubic HWC68
Yushiroken Synthetic
Water-soluble
#770TG
cutting oils
Emulcut FA-900ST
Multicool CSF-9000
Sugicut CS-68JS-1
Toyocool 3A-666
Gryton 1700
Gryton 1700D
Note: 1. The Sensor was immersed in the above oils for 240 h at 55°C and
then passed an insulation resistance test at 100 M Ω .
2. Use the kinetic viscosities and pHs in the above table as a guide
when using the Sensor in environments containing oils not listed in
the table. Additives in the oil may also affect performance. Always
test applicability in advance.
14
Oil-resistant, Robust, Compact Photoelectric Sensor
Mounting Bracket
(sold separately)
E39-L104
Kinetic
pH
viscosity at
(dilution
°
2
40
C (mm
/s)
rate)
2.02
---
Less than 10
---
10.1 ( × 30)
9.9 ( × 30)
9.9 ( × 50)
8.6 ( × 50)
9.1 ( × 30)
9.9 ( × 20)
---
9.7 ( × 30)
9.7 ( × 20)
9.6 ( × 20)
9.6 ( × 20)
9.1 ( × 10)
9.3 ( × 3)
E3ZM-C