● Wiring
Connecting and Wiring
• We recommend connecting a cable with a conductor cross-section
2
of 0.3 mm
and an outer diameter of 6 to 8 mm.
• Be sure to firmly tighten the cover in order to maintain waterproof
and dustproof properties. The screw size of the conduit sockets is
shown in the following table.
Model
E3JM-@
E3JM-@-G
E3JM-@-US
• When using the DC SSR output model, the total of the load current
for the Light-ON output (NO) and that for the Dark-ON (NC) should
be 100 mA max. If the total exceeds 100 mA, the load short-circuit
protection function will be activated (this function will be reset when
the power of the Photoelectric Sensor is turned OFF).
Cable End Treatment
Adjust the four wires to the same length when
the Ta output is to be used only. If both the Ta
and Tb outputs are to be used, treat them as
shown in the following diagram.
Recommended example
Approx.
45 mm
Power
source
Tc, Ta
Tb
Approx.
55 mm
* These parts are not provided with models with a -US suffix.
Recommended Crimp Terminal Dimensions
Round type
10 max.
7 max.
7 max.
3.6 dia. min.
19 max.
(After crimping)
Note: Use terminals with insulation tube (recommended crimp terminal: 1.25 to
3.5).
Conduit socket thread size
PF1/2
PG13.5
1/2-14NPT
Rubber bushing (provided)*
Washer (provided)*
Tightening nut (provided)*
(Unit: mm)
Fork type
10 max.
7 max.
7 max.
3.6 dia. min.
19 max.
(After crimping)
● Others
Terminal Protection Cover (Provided)
The terminal protection cover is designed to improve safety by
maintaining the sensitivity properties of the product and by preventing
any contact with charged sections while it is being operated with the
mode set to the timer mode. Mount the product as shown in the
following diagram (mount the Through-beam Model on the Receiver
side).
Ambient Conditions (Installation Area)
The E3JM will malfunction if installed in the following places.
• Places where the E3JM is exposed to a dusty environment.
• Places where corrosive gases are produced.
• Places where the E3JM is directly exposed to water, oil, or
chemicals.
E3JM
Terminal protection cover
E3JM