Amplifier Units
Type
Model NPN output E3C-LDA21
Item
PNP output E3C-LDA51
12 to 24 VDC ± 10%, ripple (p-p) 10% max.
Supply voltage
Power consumption
1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Con-
ON/OFF output
Load power supply voltage: 26.4 VDC max.; NPN/PNP (depends on model) open collector
trol out-
Load current: 50 mA max.; residual voltage: 1 V max.
put
Analog output
---
80 µ s for operation and re-
Re-
Super-high-speed
sponse
mode
set
time
250 µ s for operation and reset
High-speed mode
Standard mode
1 ms for operation and reset
High-resolution
4 ms for operation and reset
mode
Func-
Differential detec-
Switchable between single edge and double edge detection mode.
Single edge: Can be set to 250 µ s, 500 µ s, 1 ms, 10 ms, or 100 ms.
tions
tion
Double edge: Can be set to 500 µ s, 1 ms, 2 ms, 20 ms, or 200 ms.
Timer function
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments,
and 1 to 5 s set in 1-s increments)
Zero-reset
Negative values can be displayed.
Initial reset
Settings can be returned to defaults as required.
Mutual interference
Possible for up to 10 Units. (See note.)
prevention
Counter
Switchable between up
counter and down counter.
Set count: 0 to 9,999,999
I/O settings
External input setting (Se-
lect from teaching, power
tuning, zero reset, light OFF,
or counter reset.)
Digital display
Select from digital incident level + threshold or six other patterns.
Display orientation
Switching between normal/reversed display is possible.
Operating: Groups of 1 to 2 Amplifiers: − 25 ° C to 55 ° C
Ambient temperature range
Storage:
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
20 M Ω at 500 VDC
Insulation resistance
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min.
Vibration resistance
Destruction: 10 to 150 Hz, 0.7-mm double amplitude for 80 min each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s
Degree of protection
IP50 (IEC 60529)
Connection method
Prewired cable or wire-reducing connector
Weight (packed state)
With prewired cable: Approx. 100 g
With wire-reducing connector: Approx. 55 g
Materi-
Case
Polybutylene terephthalate (PBT)
als
Cover
Polycarbonate
Note: Communications are disabled if super-high-speed mode is selected, and the mutual interference prevention function and the communica-
tions function for the Mobile Console will not function.
E3C-LDA Series
External-input models
Twin-output models
E3C-LDA7
E3C-LDA11
E3C-LDA9
E3C-LDA41
100 µ s for operation and reset
---
Output setting (Select from
channel 2 output, area out-
put, or self-diagnosis.)
Groups of 3 to 10 Amplifiers: − 25 ° C to 50 ° C
Groups of 11 to 16 Amplifiers: − 25 ° C to 45 ° C
− 30 ° C to 70 ° C (with no icing)
2
, 3 times each in X, Y, Z directions
Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)
ATC-output models
E3C-LDA6
E3C-
E3C-LDA6AT
LDA11AT
E3C-LDA8
E3C-
E3C-LDA8AT
LDA41AT
Output setting (Select from
channel 2 output, area output,
self-diagnosis, or ATC error
output.)
Analog-output models
E3C-LDA11AN
E3C-LDA41AN
Control output
Voltage output: 1 to 5 VDC (con-
nected load 10 k Ω min.)
Temperature characteristics
0.3% F.S./ ° C
Response time/Repeat accuracy
Super-high-speed mode: 100 µ s/
4.0% F.S.
High-speed mode: 250 µ s/4.0%
F.S.
Standard mode: 1 ms/2.0% F.S.
High-resolution mode: 4 ms/2.0%
F.S.
Analog output setting (Offset volt-
age can be adjusted.)