[Auto Set Up]; [Network Setup] - Panasonic AK-HC5000G Operating Instructions Manual

Studio handy camera
Hide thumbs Also See for AK-HC5000G:
Table of Contents

Advertisement

Item
[TRUNK1]
[TRUNK2]
[BACK LIGHT]
[LAN]
[B/U LENS]
[T-BAR CONNECT]
[LENS I/F]
[DISPLAY STATUS/BAR
[CAM ID CHARACTER]
OSD]
[GEN-LOCK]
[H PHASE-COARSE]
[H PHASE-FINE]

[AUTO SET UP]

This cannot be set in HDR mode.
Item
[FILTER]
[SETUP MODE]
[REFERENCE FILE]
[MASTER PEDESTAL TARGET]
[AUTO SET UP EXECUTE]

[NETWORK SETUP]

[NETWORK SETUP] cannot be selected right after the power is turned on, because boot of the camera is in progress.
This is not an error. Perform operation after a while.
Item
[IP ADDRESS]
[SUBNET MASK]
[DEFAULT GATEWAY]
[HTTP PORT]
[ROP PORT]
[SET EXCUTE]
[MAC ADDRESS]
Chapter 4 Menu Operations — Menu list
Sets the serial interface standard of the <TRUNK> terminal.
[RS422], [RS232C]
f Factory setting: [RS422]
Sets the serial interface standard of the <TRUNK> terminal.
[RS422], [RS232C]
f Factory setting: [RS422]
Sets the brightness of the backlight.
[1]...[70]
f Factory setting: [20]
Sets the usage for the <LAN> terminal.
[TRUNK], [PC]
f Factory setting: [PC]
Sets the lens type of the Build-up Unit.
[PORTABLE], [BOX]
f Factory setting: [BOX]
Sets whether to connect the T-BAR unit.
[OFF], [ON]
f Factory setting: [OFF]
Sets the lens interface.
[ANALOG], [SERIAL]
f Factory setting: [SERIAL]
Sets the camera name.
Roughly adjusts the phase of horizontal synchronization.
[−5]...[+5]
f Factory setting: [0]
Finely adjusts the phase of horizontal synchronization.
[−100]...[+100]
f Factory setting: [0]
Sets the ND/CC filter mode for automatic setup.
[REF], [CURRENT]
f Factory setting: [REF]
Sets the mode for automatic setup.
[FULL], [EASY]
f Factory setting: [FULL]
Sets the reference file for automatic setup.
[FACTORY], [USER1], [USER2], [USER3], [REF1], [REF2], [REF3]
f Factory setting: [FACTORY]
Sets the master pedestal for automatic setup.
[0.0%]...[7.5%]
f Factory setting: [3.0%]
Selects whether to execute with the configured settings.
[NO], [YES]
Sets the IP address.
f Factory setting: [192.168.0.30]
Sets the subnet mask.
f Factory setting: [255.255.255.0]
Sets the default gateway.
f Factory setting: [192.168.0.1]
Sets the port number of HTTP (port number when accessing with a browser).
[1]...[65535]
f Factory setting: [80]
Sets the port number when connecting to ROP.
[49152], [49200]...[49299]
f Factory setting: [49152]
Selects whether to execute with the configured settings.
[NO], [YES]
Displays the MAC address. (This cannot be changed.)