Ordering Information/Specifications
■ Amplifier
Type
Item
Model
V600-HAR91
Power supply
24 VDC ±10%, ripple (p-p): 10%
Current consumption 130 mA max.
Input
Transistor output or contact output
Short-circuit current: 3 mA (typical) (IN terminal and 0-V short-circuit)
OFF voltage:
ON voltage:
Input impedance:
Applied voltage:
Output
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
Diagnostic functions Checks for CPU errors and transmission errors
Insulation resistance 50 MΩ max. (at 500 VDC) between cable terminals and case
Dielectric strength
500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current: 1 mA max.)
2
Intelligent Flag I/II
Read-only (8-bit)
V600-HAR81
15 to 30 VDC
0 to 5 VDC
8.2 kΩ
30 VDC max.
PNP open collector
NPN open collector
output, 20 mA max.
output, 20 mA max. at
at 30 VDC, residual
30 VDC, residual volt-
voltage: 2 V max.
age: 2 V max.
V600-HA
Multi-functional (8-bit)
V600-HAM91
V600-HAM81
PNP open collector out-
put, 20 mA max. at 30
VDC, residual voltage: 2 V
max.
Read-only (16-bit)
V600-HAR92
Transistor output
OFF voltage:
15 to 30 VDC
Input impedance:
8.2 kΩ
Short-circuit current:
3 mA (typical) (for 0-V short-circuit of
INHIBIT/TRG)
ON voltage:
0 to 5 VDC
Applied voltage:
30 VDC max.
NPN open collector output, 20 mA
max. at 30 VDC, residual voltage: 2 V
max.

Advertisement

Table of Contents
loading

Summary of Contents for Omron V600-HA

  • Page 1 Intelligent Flag I/II V600-HA Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems • Doesn't need a program and can be used like a sensor. • Advanced line construction at minimal cost. • Saves space. • Precise installation not required (Transmission distance: 100 mm max.).
  • Page 2 16 data output lines. Interface Cable V600-A60R V600-A61R V600-A62R V600-A60M V600-A61M V600-A62M Intelligent Flag I/II Read-only (16-bit) V600-HAM81 V600-HAR92 Destruction: 10 to 150 Hz, 1.5-mm double amplitude, with 4 sweeps of 8 min each in 3 directions Approx. 180 g V600-HA...
  • Page 3 V600-D2KR16: When the Data Carrier attached to the holder is mounted on a metal (ferrous) surface 5. The transmission distance specified in the specifications is also applicable when the Data Carrier is mounted on non-metallic surfaces. 6. The Data Carrier is stationary. V600-HA Intelligent Flag I/II V600-HS61 −10 to 70°C...
  • Page 4: System Configuration

    V600-A6 M Connector pins: 26 Cable lengths: 2 m, 5 m, 10 m Connector connection V600 Power V600 -HAM91/ supply -HAR92 24 VDC HAM81 Connector connection V600-HS63 V600-HS67 Wireless transmission V600 V600 V600 V600 V600 -D23P71 -D23P72 -D8KR12 -D8KR04 -D2KR16 V600-HA...
  • Page 5 –10 –5 Combinations with the V600-HS61 Sensor V600-HS61 & V600-D23P53 –8 –4 V600-HS61 & V600-D23P61 –25 –20 –15 –10 –5 V600-HA Intelligent Flag I/II V600-HS51 & V600-D23P54 –12 –8 –4 V600-HS51 & V600-D23P66N –30 –20 –10 V600-HS61 & V600-D23P54 –12 –8...
  • Page 6 –20 –10 V600-HS63 & V600-D23P71 –60 –40 –20 V600-HS63 & V600-D8KR04 –80 –60 –40 –20 Intelligent Flag I/II V600-HS63 & V600-D23P66N –50 –40 –30 –20 –10 V600-HS63 & V600-D23P72 –60 –40 –20 V600-HS63 & V600-D2KR16 –80 –60 –40 –20 V600-HA...
  • Page 7 –80 –60 –40 –20 75 × 10 DC speed 75 (mm) (conveyor 60 × 10 × 1/60 (min) 60 (ms) speed) V600-HA Intelligent Flag I/II V600-HS67 & V600-D23P66SP –80 –60 –40 –20 V600-HS67 & V600-D8KR12 –80 –60 –40 –20 V600-HAR91/-HAR81/-HAM91/-HAM81...
  • Page 8: Circuit Configuration

    Main circuit 8.2 k Ω Output Circuit Main circuit The following OMRON products cannot be connected to this product. • CVM1-OD219, C20H, C28H, C40H, or C60H Programmable Controllers • Sensor Controllers other than from the S3D2 Series When using a contact output, pay careful attention to chattering and to the minimum switching current.
  • Page 9 Type Data Carrier 1. If the Data Carrier is stationary in the transmission area for a long time when using the V600-HA@91/81 in the AUTO mode, or when using the V600-HAR92, it will drastically reduce the battery life. Therefore, stop the oscillation in the sensor either by turning off the power of the V600-HA@91/81/92 Amplifier or by setting the Inhibit input to ON.
  • Page 10 * * Enlarged Section of Mounting Hole 30û 17.5 28.3 36.3 61.8 68.5 Vinyl-insulated round cord 5.8-mm dia., 13-conductor cable, standard length: 0.5 m XG4E-2031 Mounting Hole Dimensions 2-M4 35.2 21±0.2 500 mm 28.1 44.7 V600-HA Intelligent Flag I/II 89±0.2...
  • Page 11 V600-HAM91/-HAM81 Two mounting holes * V600-HA Intelligent Flag I/II * Enlarged Section of Mounting Hole 30˚ 17.5 28.3 36.3 44.3 52.3 61.8 68.5 Vinyl-insulated round cord 5.8-mm dia., 23-conductor cable, standard length: 0.5 m XG4E-2631 Mounting Hole Dimensions 2-M4 89±0.2 35.2...
  • Page 12 Vinyl-insulated round cord (4-mm dia.) (mounting holes) Mounting Hole Dimensions 2-M4 89±0.2 35.2 21±0.2 500 mm 28.1 52.3 Case: Brass Transmission window: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) Case: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) V600-HA Intelligent Flag I/II...
  • Page 13 V600-HS63 Power indicator (green) V600-HS67 Power indicator (green) Interface Cable V600-A6@R (for V600-HAR91/-HAR81)) V600-HA Intelligent Flag I/II Two, 4.5-dia. mounting holes 2-R5 4-R1 Bushing Case: ABS resin Filter: Epoxy resin Cable: PVC (oil-resistant) ± 0.2 ± 0.2 +100 20 ±5 20 ±5...
  • Page 14 V600-A6@M (for V600-HAM91/-HAM81/-HAR92) Model L (m) V600-A60R/60M V600-A61R/61M V600-A62R/62M +100 20 ±5 20 ±5 20 ±5 Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.), 23-conductor cable, standard length: 2 m Intelligent Flag I/II 10.6 30 ±5 37.6 XG5M-2632-N Connector V600-HA...
  • Page 15: Terms And Conditions

    The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list Complete terms and conditions for product purchase and use are on Omron’s website at www.omron.com/oei – under the “About Us” tab, in the Legal Matters section.

This manual is also suitable for:

V600-har91V600-har81V600-ham91V600-ham81V600-har92

Table of Contents