D. Vertical Termination Requirements
Install Metal Roof Flashing
• See minimum vent heights for various pitched roofs
(Figure 7.9) to determine the length of pipe to extend
through the roof.
• Slide the roof 昀氀ashing over the pipe sections extending
through the roof as shown in Figure 7.10.
Note: When installing a silicone or EPDM pipe 昀氀ashing boot
on a metal roof, it is recommended to put a bead of 100%
silicone sealant where the boot contacts the vent pipe to
prevent the entry of water. Follow the manufacturer's recom-
mendations when installing the boot.
2 FT.
20 INCHES MIN.
MIN.
DISCHARGE
GAS DIRECT VENT
TERMINATION CAP
Roof Pitch
Flat to 6/12........................................1.0*
Over 6/12 to 7/12 ............................ 1.25*
Over 7/12 to 8/12 .............................. 1.5*
Over 8/12 to 9/12 .............................. 2.0*
Over 9/12 to 10/12 ............................ 2.5*
Over 10/12 to 11/12 ......................... 3.25
Over 11/12 to 12/12 ........................... 4.0
Over 12/12 to 14/12 ........................... 5.0
Over 14/12 to 16/12 ........................... 6.0
Over 16/12 to 18/12 ........................... 7.0
Over 18/12 to 20/12 ........................... 7.5
Over 20/12 to 21/12 ........................... 8.0
* H minimum may vary depending on regional snowfall.
Refer to local codes.
Figure 7.9 Minimum Height From Roof To Lowest Discharge
Opening
Heat & Glo • TRUE-36-IFT, TRUE-42-IFT, TRUE-50-IFT Installation Manual • 2461-980 Rev. Y • 6/23
HORIZONTAL
OVERHANG
VERTICAL
WALL
LOWEST
OPENING
X
12
ROOF PITCH
IS X/ 12
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
H (Min.) Ft.
NOTICE: Failure to properly caulk the roof 昀氀ashing and
pipe seams could permit entry of water.
• Caulk the gap between the roof 昀氀ashing and the outside
diameter of the pipe.
• Caulk the perimeter of the 昀氀ashing where it contacts the
roof surface. See Figure 7.10.
• Caulk the overlap seam of any exposed pipe sections
that are located above the roof line.
Figure 7.10
Figure 7.10
Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
• Slide the storm collar onto the exposed pipe section
and align brackets.
• Insert a bolt (provided) through the brackets and install
nut. Do not completely tighten.
Figure 7.11 Insert Bolt into Brackets
Figure 7.11 Insert Bolt into Brackets
• Slide the assembled storm collar down the pipe section
until it rests on the roof 昀氀ashing. See Figure 7.11.
• Tighten nut and make sure the collar is tight against the
pipe section.
• Caulk around the top of the storm collar. See Figure 7.12.
CAULK
39