Bacharach 100 Operation & Maintenance Manual page 10

Combustion gas analyzer
Table of Contents

Advertisement

Operating Time ................................. Up to 18 hours contnuous (pump
Warm Up Time . .................................. 10 or 60 seconds, dependent on
Memory
(Model 105/110/120/125) . .................... Up to 10 sets of readngs can be
Display ................................................. 4 Dgt, 2 Lne, 7-segment Lqud
Front Panel Controls ....................... Sx push button swtches
Accuracy:
• Oxygen............................................. ±0.3% O
• Carbon Monoxde ............................ ±5% of readng or ±10 ppm, whch-
• Flue Gas Temperature . ................... ±4 °F between 32 & 255 °F
• Second Thermocouple Channel ...... ±4 °F between 32 & 212 °F
• Ambent Temperature..................... ±4 °F between 32 & 104 °F
• Draft ................................................ ±1% of readng or ±0.02 nWC
* Tghter CO accuracy n the lower ranges, up to ±2 ppm, may be
attaned f a lower range calbraton gas (e.g. 100 ppm CO) s used.
4
Fyrite Pro
runnng and backlght off)
analyzer's model and setup (Refer
to Secton 4.13.1)
saved n memory. When memory
s full, the next readng saved wll
overwrte the oldest readng.
Crystal Dsplay
(Refer to Secton 3.4)
2
concentraton of CO
ever s greater*
(±2 °C between 0 & 124 °C)
±6 °F between 256 & 480 °F
(±3 °C between 125 & 249 °C)
±8 °F between 481 & 752 °F
(±4 °C between 250 & 400 °C)
(±2 °C between 0 & 100 °C)
(±2 °C between 0 & 40 °C)
(±0.05 mB), whchever s greater
wth a typcal flue gas
2
Instruction 24-9395

Advertisement

Table of Contents
loading

This manual is also suitable for:

100 printer kit105110120125125 printer kit ... Show all