Maintenance
Lubricating system
5.7.5 Replacing centrifuge paper filter — SL102
WARNING
Hazards by hot engine oil!
Serious injuries or death by burns or skin penetrating oil.
u Avoid skin contact with the engine oil.
u Wear proper personal protective equipment.
Ensure that:
q Preparatory maintenance activities are fullfilled.
maintenance activities, page 91)
q Original KOHLER oil filters with the seals are provided.
q A suitable drainage container is available.
q The required quantity of approved oil is provided.
and operating fluids, page 120)
The oil centrifuge is equipped with a stop valve which stops the oil inlet.
The oil centrifuge is attached to the engine on the right side.
Replacing centrifuge paper filter
Fig. 59: Oil centrifuge
1
Centrifuge base
2
V-clamp
3
Rotor
4
Cover
104
(For more information see: 5.5 Preparatory
5
6
7
8
© 2019 by Kohler Co. All rights reserved.
Operation and Maintenance Manual
(For more information see: 5.11 Lubricants
Rotor cylinder
Paper filter
Rotor base
Rotor cover
KD62V12 33521030301_6_1 EN_US
2019-02