Fig. 65: Assembling rotor
u Assemble rotor cylinder 5 on rotor base 7.
u Mount rotor cover 8 and tighten nut to 40 Nm (30 ft-lb).
Fig. 66: Assembling the centrifuge
u Place rotor 3 in centrifuge base 1.
u Install cover 4 and tighten nut to 7 Nm (5 ft-lb).
u Check seal of V-clamp 2. Replace if necessary.
u Install and tighten V-clamp 2 to 7 Nm (5 ft-lb).
u Start and run engine for three minutes.
u Check engine oil level.
page 101)
5.7.6 Changing Diesel engine oil — SL101, SL101bis, SL121
WARNING
Hazards by hot engine oil!
Serious injuries or death by burns or skin penetrating oil.
u Avoid skin contact with the engine oil.
u Wear proper personal protective equipment.