Garantía Limitada - Campbell Hausfeld WG2060 Operating Instructions And Parts Manual

Campbell hausfeld operating instruction wire feed arc welder wg2060 and wg2064
Table of Contents

Advertisement

Soldadora Por Arco Con Alimentación de Cable
Garantía Limitada
Garantía Limitada 5-3-1
1.Duración: El fabricante garantiza que reparará, sin costo alguno, por piezas o mano de obra, la soldadora, pistola de
soldadura o cables que demuestren estar defectuosos, en material o mano de obra, durante el(los) siguiente(s) periodo(s) a
partir de la fecha de compra al por menor original:
Por 5 años: el transformador y rectificador de la soldadora.
Por 3 años: toda la soldadora (salvo las abrazaderas, pistola de soldadura, sujetador de electrodo, cables o accesorios
embalados con la soldadora).
Por 1 año:
las abrazaderas de soldadura, pistola MIG, sujetador de electrodo, accesorios y cables de soldadura (como
sea pertinente).
2.¿Quién emite esta garantía? (Garante)
Campbell Hausfeld / A Scott Fetzer Company
100 Production Drive
Harrison, OH 45030
Teléfono: (513)-367-4811
3.¿Quién recibe esta garantía? (Comprador): El comprador original del producto Campbell Hausfeld.
4.¿Qué es lo que cubre esta garantía?: Defectos de material y mano de obra que ocurran dentro del período de duración
de la garantía. Esta garantía se extiende solamente a la soldadora, el transformador y rectificador de la soldadora, pistola
de soldadura o sujetador de electrodo y cables.
5.¿Qué es lo que no cubre esta garantía?:
A.Las garantías implícitas, incluyendo las de comerciabilidad e IDONEIDAD PARA UN FIN PARTICULAR, SE LIMITAN A LA
DURACIÓN DE ESTA GARANTÍA EXPRESA. Luego de este periodo, todos los riesgos de pérdida, por cualquier razón,
corren por cuenta del comprador.
Algunos estados no permiten la limitación de la duración de una garantía implícita,
de modo que estas restricciones tal vez no rijan para Ud.
B. CUALQUIER PERDIDA, DAÑO O GASTO INCIDENTAL, INDIRECTO O RESULTANTE QUE PUEDA DERIVARSE DE CUALQUIER
DEFECTO, FALLA O MAL FUNCIONAMIENTO DEL PRODUCTO DE CAMPBELL HAUSFELD. Algunos estados no permiten la
exclusión o limitación de los daños incidentales o derivados, por lo que esta restricción tal vez no rija para Ud.
C. Esta garantía no se aplica a cualquier accesorio incluido en el producto que está sujeto a desgaste por uso; la reparación
o cambio de este accesorio correrá por cuenta del propietario. Estos artículos MIG incluyen, sin sentido limitativo, a las
puntas de contacto, boquillas, revestimientos de pistola, rodillos de mando, limpiador de cable de fieltro. Además, esta
garantía no se extiende a los daños causados por el cambio o mantenimiento fuera de tiempo de cualquiera de las
piezas CONSUMIBLES enumeradas anteriormente.
D.Cualquier falla que resulte de un accidente, mal uso del comprador, negligencia u omisión en operar los productos de
acuerdo a las instrucciones provistas en el manual del propietario suministrado con el producto.
E. Servicio de pre-entrega, es decir, ensamblaje y ajuste.
7.Responsabilidades del garante bajo esta garantía: Reparar o reemplazar, a opción del garante, los productos o
componentes que hayan funcionado mal dentro del período de garantía.
8.Responsabilidades del comprador bajo esta garantía:
A.Entregar o enviar el producto o componente de Campbell Hausfeld al Centro de Servicio Autorizado de Campbell
Hausfeld más cercano. Los costos de envío, si los hubiera, serán por cuenta del comprador.
B. Hacer uso de un cuidado razonable en la operación y mantenimiento de los productos descritos en el manual del
propietario.
9.¿Cuándo efectuará el garante la reparación o reemplazo bajo esta garantía?: La reparación o reemplazo se
programará y efectuará de acuerdo al flujo normal de trabajo en la localidad de servicio y dependiendo de la
disponibilidad de repuestos.
Esta garantía limitada le proporciona a Ud. derechos legales específicos y es probable que Ud. tenga otros derechos, los
cuales varían de un estado a otro.
42 Sp
to performing any electric arc welding
General Safety
operations.
(Continued)
G Route wire gun and work cables
G Do not operate any electric arc
together and secure with tape when
welder in areas where flammable or
possible.
explosive vapors may be present.
G Never wrap arc welder cables around
G Take precautions to ensure flying
the body.
sparks and heat do not cause flames
G Always position wire gun and work
in hidden areas, cracks, etc.
leads on the same side of the body.
Fire hazard! Do not
G Exposure to electromagnetic fields
WARNING
!
weld on containers
during welding may have other
or pipes that contain or have contained
health effects which are not known.
flammable materials or gaseous or liquid
combustibles.
WARNING
!
WARNING
!
secure and free of hazards (sparks,
flames, glowing metal or slag) prior to
Arc welding closed
leaving. Be sure equipment is turned off
cylinders or containers
and excess wire is cut off. Be sure cables
such as tanks or drums
are loosely coiled and out of the way. Be
can cause explosion if
sure all metal and slag has cooled.
not properly vented!
Verify that any cylinder or container to
DANGER
!
be welded has an adequate ventilation
hole, so that expanding gases can be
Cylinders can explode if damaged.
released.
Shielding gas cylinders
contain gas under high
WARNING
!
pressure. If damaged, a
cylinder can explode.
Do not breathe fumes
Since gas cylinders are
produced by arc
normally part of the
welding operation.
welding process, be
These fumes are
sure to treat them carefully.
dangerous. If welding
area cannot be adequately ventilated,
G Protect compressed gas cylinders
be sure to use an air-supplied
from excessive heat, mechanical
respirator.
shocks and arcs.
G Keep head and face out of welding
G Install and secure cylinders in an
fumes.
upright position by chaining them
G Extremely toxic fumes are created
to stationary support or equipment
when galvanized or cadmium plated
cylinder rack to prevent falling or
metals or metals which contain zinc,
tipping.
mercury or beryllium are heated.
G Keep cylinders away from any
Complete the following precautions
welding or other electrical circuits.
before performing electric arc
G Never allow a welding electrode to
welding operations on these metals:
touch any cylinder.
a. Remove coating from base metal.
G Use only correct shielding gas
b. Make sure welding area is well
ventilated.
cylinders, regulators, hoses and
fittings designed for the specific
c. Use an air-supplied respirator.
application; maintain all parts
WARNING
!
properly.
The electromagnetic field
G Turn face away from valve outlet
generated during arc
when opening cylinder valve.
welding may interfere
with the operation of
G Keep protective cap in place over
various electrical and
valve except when cylinder is in use
electronic devices such as cardiac
or connected for use.
pacemakers. Persons using such devices
G Read and follow instructions on
should consult with their physician prior
compressed gas cylinders, associated
Models WG2060 and WG2064
equipment, and CGA publication P-1
listed in Safety Standards.
Never use
DANGER
!
flammable gasses
with MIG welders. Only inert or non-
flammable gasses such as carbon
dioxide, argon, helium or mixtures of
one or more of these gasses are
suitable for MIG welding.
Never lift cylinders
WARNING
!
off the ground by
their valves or caps or with chains or
slings.
Always be sure
welding area is
ADDITIONAL SAFETY STANDARDS
ANSI Standard Z49.1 from American
Welding Society, 550 N.W. Le June Rd.
Miami, FL 33126
Safety and Health Standards
OSHA 29 CFR 1910, from Superintendent
of Documents, U.S. Government Printing
Office, Washington, D.C. 20402
National Electrical Code
NFPA Standard 70, from National Fire
Protection Association, Batterymarch
Park, Quincy, MA 02269
Safe Handling of Compressed Gases
in Cylinders
CGA Pamphlet P-1, from Compressed Gas
Association, 1235 Jefferson Davis
Highway, Suite 501, Arlington, VA 22202
Code for Safety in Welding and
Cutting
CSA Standard W117.2, from Canadian
Standards Association, Standards Sales,
178 Rexdale Boulevard, Rexdale, Ontario,
Canada M9W 1R3
Cutting And Welding Processes
NFPA Standard 51B, from National Fire
Protection Association, Batterymarch
Park, Quincy, MA 02269
Safe Practices For Occupational And
Educational Eye And Face Protection
ANSI Standard Z87.1, from American
National Standards Institute, 1430
Broadway, New York, NY 10018
Refer to Material Safety Data Sheets and
manufacturers instructions for metals,
wire, coatings and cleaners.
www.chpower.com
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wg2064

Table of Contents