before they can go into the tube. Only small dust
particles go with the air to the inlet.
6.4.2 To replace the filter
When the power starts to decrease, replace the air filter.
Note: The air filter cannot be cleaned.
1. Remove the air filter.
32 - Repair and servicing
CAUTION: Make sure that dust does not fall
into the carburetor inlet.
2. Clean and examine the inlet duct.
a) Make sure that there is no dust on the inner
surface of the inlet duct. If there is dust, the inlet
duct is damaged and must be replaced.
b) Clean dry dust from the outer surface of the inlet
duct with compressed air or a vacuum cleaner.
c) Clean material from wet cutting mechanically.
3. Install a new air filter.