Operation - Campbell Hausfeld FP2040 Operating Instructions And Parts Manual

Oilless compressors
Table of Contents

Advertisement

Available languages

Available languages

Installation
(Continued)
DANGER
!
Improper use of
grounding plug can result
in a possible risk of
electrical shock!
Do not use a
DANGER
!
grounding adapter
with this product!
2. If repair or replacement of cord or plug
is necessary, do not connect grounding
wire to either flat blade terminal. The
wire with insulation having an external
surface that is green (with or without
yellow stripes) is the grounding wire.
Never connect
WARNING
!
green (or green and
yellow) wire to a live terminal.
3. Check with a qualified electrician or
serviceman if grounding instructions
are not completely understood, or if in
doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.
WIRING
Overheating, short
CAUTION
!
circuiting and fire
damage will result from inadequate
wiring, etc.
NOTE: 120 volt, 15 amp units can be
operated on a 120 volt circuit under the
following conditions:
a. No other electrical appliances or lights
are connected to the same branch
circuit.
b. Voltage supply is normal.
c. Circuit is equipped with a 15 amp
circuit breaker or a 15 amp slow blow
fuse.
If these conditions cannot be met or if
nuisance tripping of current protection
Length of Cord (ft)
Gauge of Cord
Drain Petcock
Figure 2 - Unit Identification
device occurs, it may be necessary to
operate compressor from a 120 volt, 20
amp circuit.

Operation

Regulator - The regulator controls the
amount of air pressure released at the
hose outlet.
ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Handle - Designed to move the
compressor.
Drain Petcock - This valve is located on
the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.
Reduce tank pressure below 10 psi,
then drain moisture from tank daily to
avoid tank corrosion. Drain moisture
from tank(s) by opening the drain
petcock located underneath the tank.
LUBRICATION
This is an oilless product and DOES
NOT require lubrication to operate.
Extension cords for 120V/8 Amp Unit
25
50
100
18
14
12
Handle
Safety Valve
150
200
10
8
3
ON/OFF Switch
Regulator
BREAK-IN PROCEDURE
Do not attach air
CAUTION
!
chuck or other tool
to open end of hose until start-up has
been completed and unit checks OK.
IMPORTANT: Do not operate
compressor before reading instructions
or damage may result.
1. Turn regulator fully clockwise to
open air flow.
2. Turn switch to OFF position and plug
in power cord.
3. Turn switch to ON position and run
unit for 5 minutes to break in the
pump parts.
4. Turn regulator knob fully
counterclockwise. Compressor will
build to maximum preset pressure
and shut off.
5. Turn regulator knob clockwise to
cause air to bleed off. Compressor
will restart at a preset pressure.
6. Turn regulator knob
counterclockwise to shut off the air
and turn switch to Off position.
250
300
400
8
6
6
www.chpower.com
FP2040
500
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents