Campbell Hausfeld Oilless Compressors FP209002L Operating Instructions And Parts Manual
Campbell Hausfeld Oilless Compressors FP209002L Operating Instructions And Parts Manual

Campbell Hausfeld Oilless Compressors FP209002L Operating Instructions And Parts Manual

Oilless compressors
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These units
operate without oil. Compressed air
from this unit will contain moisture.
Install a water filter or air dryer if
application requires dry air.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates an
imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before putting
unit into service. In case of questions,
damaged or missing parts, please call 1-
800-543-6400 for customer assistance.
Have the date code, model number,
and parts list (with missing parts
circled) before calling.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2008 Campbell Hausfeld/Scott Fetzer
Oilless Compressors
DO NOT RETURN THE
PRODUCT TO THE
STOP!
RETAILER! CALL
1-800-543-6400
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No. ____________________
Date Code ____________________
Date of purchase _________________
Retain these numbers for future
reference.
Do not operate
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety
Information
CALIFORNIA PROPOSITION 65
This product
or its power cord
may contain chemicals known to the
State of California to cause cancer and
birth defects or other reproductive
harm. Wash hands after handling.
GENERAL SAFETY INFORMATION
Since the air compressor and other
components used (filters, lubricators,
hoses, etc.), make up a high pressure
pumping system, the following safety
precautions must be observed at all times:
For parts, product & service information
visit www.chpower.com
FP209800L

Breathable Air Warning

This compressor/pump is not
equipped and should not be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety
and alarm equipment. This
additional equipment is necessary
to properly filter and purify the air
to meet minimal specifications for
Grade D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
1. Read all manuals included
with this product carefully.
Be thoroughly familiar
with the controls and the
proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the US, National
Electrical Codes (NEC) and Occupational
Safety and Health Act (OSHA).
IN626700AV 7/08
MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Campbell Hausfeld Oilless Compressors FP209002L

  • Page 1: Breathable Air Warning

    (with missing parts circled) before calling. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2008 Campbell Hausfeld/Scott Fetzer Oilless Compressors DO NOT RETURN THE...
  • Page 2: General Safety Information

    Oilless Compressors General Safety Information (Continued) 3. Only persons well acquainted with these rules of safe operation should be allowed to use the compressor. 4. Keep visitors away and NEVER allow children in the work area. 5. Wear safety glasses and use hearing protection when operating the pump or unit.
  • Page 3: Operation

    Installation (Continued) 2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire. Never connect green (or green and yellow) wire to a live terminal.
  • Page 4: Maintenance

    Oilless Compressors Operation (Continued) 6. Adjust regulator to proper pressure for tool or tire. Operate tool per instructions. As air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cycle on and off automatically.
  • Page 5 FP209800 Notes www.chpower.com...
  • Page 6: Troubleshooting Chart

    Oilless Compressors Troubleshooting Chart Symptom Possible Cause(s) Compressor will not run 1. Switch in OFF position 2. No electrical power at wall outlet 3. Compressor has reached automatic shut-off pressure 4. Motor overheated 5. Loose electrical connection 6. ON / OFF switch bad 7.
  • Page 7: Replacement Parts List

    Please provide following information: - Model number - Serial number (if any) - Part description and number as shown in parts list Address parts correspondence to: Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A. Replacement Parts List Ref.
  • Page 8: Limited Warranty

    B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
  • Page 9: Directives De Sécurité

    (avec les parties manquantes encerclées) avant d’appeler. MÉMENTO : Gardez votre preuve datée d’achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2008 Campbell Hausfeld/Scott Fetzer Compresseur Sans Huile NE PAS RENVOYER LE PRODUIT AU ARRÊT!
  • Page 10 Compresseur Sans Huile Généralités sur la Sécurité (Suite) 3. Seules les personnes bien familiarisées avec ces règles d’utilisation doivent être autorisées à se servir du compresseur. 4. Garder les visiteurs à l’écart de/et NE JAMAIS permettre les enfants dans l’endroit de travail. 5.
  • Page 11 Installation (Suite) Ne pas utiliser un adaptateur de mise à la terre avec ce produit ! 2. Si la réparation ou le remplacement du cordon ou de la fiche est nécessaire, ne pas connecter le fil de terre à ni une ni l’autre borne plate. Le fil avec l’isolation qui a une surface externe verte (avec ou sans rayures) est le fil de terre.
  • Page 12: Entretien

    Compresseur Sans Huile Fonctionnement (Suite) 6. Mettre l’interrupteur marche/arrêt à la position « OFF » (ARRÊT). 7. Débrancher le cordon d’alimentation. AVANT CHAQUE DÉMARRAGE - PROCÉDURE DE FONCTIONNEMENT 1. Tourner l’interrupteur à la position « OFF » ARRÊT ( O ) et brancher le cordon d’alimentation.
  • Page 13 Entretien (Suite) 3. En portant des lunettes de sécurité, vidanger l’air du réservoir en tirant l’anneau de la soupape de sécurité. À l’aide de l’autre main, détourner l’air se déplaçant rapidement, pour protéger le visage. Notes 4. Vidanger le réservoir de toute condensation en ouvrant le robinet de vidange au fond du réservoir.
  • Page 14: Guide De Dépannage

    Compresseur Sans Huile Guide de Dépannage Symptôme Cause(s) Possible(s) Le compresseur ne 1. Interrupteur en position “OFF” fonctionne pas. (arrêt). 2. Aucun courant à la prise de courant murale 3. Le compresseur a atteint la pression d’arrêt automatique 4. Moteur surchauffé 5.
  • Page 15: Liste De Pièces De Rechange

    - Numéro du modèle - Numéro de série (si applicable) - Description de la pièce et son numéro sur la liste de pièces Correspondance concernant les pièces : Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A.
  • Page 16: Garantie Limitée

    2. GARANTIE ACCORDÉE PAR (GARANT) : Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone : (800) 543-6400 3. BÉNÉFICIAIRE DE CETTE GARANTIE (ACHETEUR) : L’acheteur original (sauf en cas de revente) du produit Campbell Hausfeld. 4. PRODUITS COUVERTS PAR CETTE GARANTIE : N’importe quel compresseur d’air Campbell Hausfeld.
  • Page 17: Medidas De Seguridad

    (con las partes que faltan marcadas con un círculo) antes de llamar. RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. © 2008 Campbell Hausfeld/Scott Fetzer Compresores Sin Aceite ¡NO DEVUELVA EL...
  • Page 18: Instalación

    Compresores Sin Aceite Informaciones Generales de Seguridad (Continuación) 5. Siempre use anteojos de seguridad y protéjase los oídos para operar el cabezal o el compresor. 6. No se encarame sobre el cabezal, ni lo use para sostenerse. 7. Antes de cada uso, inspeccione el sistema de aire comprimido y los componentes eléctricos, para ver si están dañados, deteriorados,...
  • Page 19 Instalación (Continuación) Si necesita reparar o reemplazar el cordón o el enchufe, no conecte el cable de conexión a tierra a ninguno de los terminales planos. El alambre cuya superficie externa del aislante es verde, con o sin rayas amarillas, es el cable de conexión a tierra.
  • Page 20: Mantenimiento

    Compresores Sin Aceite Funcionamiento (Continuación) ANTES DE INICIAR CADA PROCEDIMIENTO DE ENCENDIDO 1. Coloque el interruptor en OFF ( O ) y conecte el cordón al tomacorrientes. 2. Gire la perilla del regulador en sentido antihorario para cerrar el flujo de aire. 3.
  • Page 21 FP209800 Notas 21 Sp...
  • Page 22: Guía De Diagnóstico De Averías

    Compresores Sin Aceite Guía de diagnóstico de averías Problema Posible(s) Causa(s) El compresor no 1. El interruptor está en la posición OFF funciona (apagado) 2. No hay corriente eléctrica en el tomacorriente de la pared 3. El compresor alcanzó la presión de corte automático 4.
  • Page 23: Lista De Repuestos

    Sírvase darnos la siguiente información: - Número del modelo - Número de Serie (de haberlo) - Descripción y número del repuesto según la lista de repuestos Puede escribirnos a: Campbell Hausfeld Attn: Customer Service 100 Production Drive Harrison, OH 45030 U.S.A. Lista de Repuestos No.
  • Page 24: Garantía Limitada

    1. DURACION: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Un año. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.

This manual is also suitable for:

Fp209800

Table of Contents