See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions and Parts List
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Oilless Compressors
REGISTER YOUR PRODUCT ONLINE NOW!
Description
Oilless compressors are designed for
do-it-yourselfers with a variety of
home and automotive jobs. These
units operate without oil. Compressed
air from this unit will contain moisture.
Install a water filter or air dryer if
application requires dry air.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make
sure to tighten fittings, bolts, etc.,
before putting unit into service. In
case of questions, damaged or missing
parts, please call 1-800-543-6400 for
customer assistance.
Have the date code, model number,
and parts list (with missing parts
circled) before calling.
DO NOT RETURN
THE PRODUCT TO
STOP!
THE RETAILER!
Do not operate
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
READ & FOLLOW ALL
INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2012
Record the Model No., Serial No.
and date of purchase located on the
base below the pump in the space
below.
Model No.
___________________
Serial No.
___________________
Date of purchase
Retain these numbers for
future reference.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe
the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or
serious injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death
or serious injury.
Attach it to this manual or file it for safekeeping.
http://www.chpower.net/reg
Breathable Air Warning
This compressor/pump is not
equipped and should not be
used "as is" to supply breathing
quality air. For any application
of air for human consumption,
the air compressor / pump
will need to be fitted with
suitable in-line safety and alarm
equipment. This additional
equipment is necessary to
properly filter and purify the air
to meet minimal specifications
for Grade D breathing as
described in Compressed
Gas Association Commodity
Specification G 7.1 - 1966,
OSHA 29 CFR 1910. 134,
and/or Canadian Standards
____________
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor
is used for the purpose of
breathing air application
and proper in-line safety
and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
the Manufacturer disclaims any
liability whatsoever for any loss,
personal injury or damage.
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
information, that if not followed,
may cause damage to equipment.
NOTE: Information that requires
special attention.
FP2095, FP2096 Series
Caution indicates
a potentially
Notice indicates
important
IN619404AV 5/12

Advertisement

Table of Contents
loading

Summary of Contents for Campbell Hausfeld FP2096 Series

  • Page 1 See Warranty on page 8 for important information about commercial use of this product. FP2095, FP2096 Series Operating Instructions and Parts List Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
  • Page 2: General Safety Information

    Operating Instructions and Parts List FP2095, FP2096 Series General Safety Information 13. Tanks rust from moisture build-up, Motors, which weakens the tank. Make electrical CALIFORNIA PROPOSITION 65 sure to drain tank regularly and equipment and controls can This product or its...
  • Page 3 Operating Instructions and Parts List FP2095, FP2096 Series Introduction Regulator - The regulator controls Drain Valve - This valve is located on the amount of air pressure released at the bottom of the tank. Use this valve R efer to Figure 3 to locate the the hose outlet.
  • Page 4 Operating Instructions and Parts List FP2095, FP2096 Series 2. If repair or replacement of cord or BEFORE EACH START-UP Installation OPERATING PROCEDURE plug is necessary, do not connect LOCATION grounding wire to either fl at blade 1. Turn regulator knob fully It is extremely important to use the terminal.
  • Page 5: Drain Tank

    Operating Instructions and Parts List FP2095, FP2096 Series ASME SAFETY VALVE OVERLOAD PROTECTOR MOISTURE IN COMPRESSED AIR Do not remove or This compressor Moisture in compressed air will attempt to adjust is equipped with form into droplets as it comes...
  • Page 6: Troubleshooting Chart

    Operating Instructions and Parts List FP2095, FP2096 Series Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. Switch in OFF position 1. Make sure compressor is plugged in and switch is ON. 2. No electrical power at wall outlet 2.
  • Page 7: Repair Part Kits

    Operating Instructions and Parts List FP2095, FP2096 Series For replacement parts or technical assistance, call 1-800-543-6400 Please provide following information: Address any correspondence to: - Model number Attn: Customer Service - Serial number (if any) 100 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 Ref.
  • Page 8: Limited Warranty

    8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the purchaser. C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
  • Page 9 Voir la Garantie à la page 16 pour de l’information importante sur l’utilisation commercial de ce produit. Série FP2095, FP2096 Instructions d’Utilisation et Manual de Pièces Veuillez lire et conserver ces instructions. Lire attentivement avant de commencer à assembler, installer, faire fonctionner ou entretenir l'appareil décrit.
  • Page 10: Généralités Sur La Sécurité

    Instructions d’Utilisation et Manual de Pièces Série FP2095, FP2096 Généralités sur la Sécurité 13. L’accumulation d’humidité cause la rouille qui peut affaiblir le PROPOSITION 65 DE CALIFORNIE réservoir. Purger le réservoir moteurs, l’équipement et Ce produit ou son régulièrement et l’inspecter les commandes électriques cordon peuvent peuvent causer des arcs...
  • Page 11 Instructions d’Utilisation et Manual de Pièces Série FP2095, FP2096 Introduction Manomètre - Ce manomètre indique Réinitialisation du moteur - (non la pression d’air mesurée en psi dans visible, située à l’intérieur du moteur). Se référer à la Figure 4. le réservoir du compresseur. S’assurer Conçue pour éviter la surchauffe Interrupteur MARCHE/ARRÊT (I/O) - que le manomètre est à...
  • Page 12 Instructions d’Utilisation et Manual de Pièces Série FP2095, FP2096 2. Si la réparation ou le AVANT CHAQUE DÉMARRAGE - Installation remplacement du cordon ou PROCÉDURE DE FONCTIONNEMENT ENDROIT de la fi che est nécessaire, ne 1. Tourner le bouton du régulateur Il est extrêmement important pas connecter le fi...
  • Page 13: Horaire D'entretien

    Instructions d’Utilisation et Manual de Pièces Série FP2095, FP2096 1. Éteindre le compresseur et dégager PURGER LE RÉSERVOIR HUMIDITÉ DANS L’AIR la pression du système. (Pour Avec le compresseur hors circuit et la COMPRIMÉ dégager la pression du système, pression dissipée, purger l’humidité L’humidité...
  • Page 14: Guide De Dépannage

    Instructions d’Utilisation et Manual de Pièces Série FP2095, FP2096 Guide De Dépannage Symptôme Cause(s) possible(s) Mesure(s) corrective(s) Le compresseur ne 1. Interrupteur à la position OFF (arrêt) 1. S’assurer que le compresseur est branché et l’interrupteur à fonctionne pas. ON (marche). 2.
  • Page 15 Instructions d’Utilisation et Manual de Pièces Série FP2095, FP2096 Pour pièces de rechange ou assistance technique, appeler 1-800-543-6400 S’il vous plaît fournir l’information suivante: Adresser toute correspondance à: - Numéro de modèle Attn: Customer Service - Code imprimé sur l’unité 100 Production Drive - Description de la pièce et son numéro Harrison, OH 45030...
  • Page 16: Garantie Limitée

    8. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE : A. Fournir une preuve d’achat datée et un état d’entretien. B. Appelez Campbell Hausfeld (800-543-6400) pour obtenir vos options de service sous garantie. Les frais de transport sont la responsabilité de l’acheteur.
  • Page 17 Ver la Garantía en página 24 para información importante sobre el uso comercial de este producto. Serie FP2095, FP2096 Manual de Instrucciones de Operación y Lista de Piezas Por favor lea y guarde estas instrucciones. Léalas cuidadosamente antes de tratar de montar, instalar, operar o dar mantenimiento al producto aquí...
  • Page 18 Manual de Instrucciones de Operación y Lista de Piezas Serie FP2095, FP2096 Informaciones Generales de ¡Nunca Seguridad trate de reparar o modifi car motores, equipos eléctricos PROPOSICIÓN 65 DE CALIFORNIA el tanque! Al soldarlo, y controles, pueden Este producto, taladarle orifi cios o ocasionar arcos eléctricos o su cable de modifi...
  • Page 19 Manual de Instrucciones de Operación y Lista de Piezas Serie FP2095, FP2096 Introducción Manómetros - Hay dos tipos Reinicio del motor - (no se muestra, de manómetros ubicados cerca ubicado dentro del motor). Diseñado Vea la Figura 3. del regulador. Estos manómetros para evitar que el motor se recaliente.
  • Page 20: Instalación

    Manual de Instrucciones de Operación y Lista de Piezas Serie FP2095, FP2096 2. Si necesita reparar o reemplazar 7. Desenchufe el cable de corriente. Instalación el cordón o el enchufe, no conecte Ahora el compresor está listo para ser COLOCACIÓN el cable de conexión a tierra a usado.
  • Page 21: Mantenimiento

    Manual de Instrucciones de Operación y Lista de Piezas Serie FP2095, FP2096 Desvíe el aire cubriendo la válvula DRENAJE DEL TANQUE HUMEDAD EN EL AIRE con una mano mientras tira del Apague el compresor y libere toda COMPRIMIDO anillo con la otra mano.) Tire del la presión, después: Abra la llave de La humedad que se acumula en anillo hasta vaciar el tanque.
  • Page 22: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación y Lista de Piezas Serie FP2095, FP2096 Guía de Diagnóstico de Averías Problema Posible(s) Causa(s) Acción a Tomar El compresor no funciona 1. El interruptor está en la posición 1. Asegúrese de que el compresor esté enchufado y que el OFF (apagado) interruptor esté...
  • Page 23 Manual de Instrucciones de Operación y Lista de Piezas Serie FP2095, FP2096 Para ordenar repuestos, sírvase llamar al distribuidor más cercano a su domicilio Sírvase darnos la siguiente información: Puede escribirnos a: - Número del modelo Attn: Customer Service - Número de serie (de haberlo) 100 Production Drive - Descripción y número del repuesto según la lista de repuestos Harrison, OH 45030...
  • Page 24: Garantía Limitada

    1. DURACION: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Un año. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.

This manual is also suitable for:

Fp2095 series

Table of Contents