CHARGING SYSTEM

Charging wire diagram
yellow
alternator
Current Leakage Inspection
Turn the main switch to OFF position, and
remove the negative cable terminal (-) from
the battery.
Connect an ammeter between the negative
cable terminal and the battery negative
terminal (as shown on left diagram).
Caution
In the current leakage test, set the
current range at larger scale, then
gradually decrease to the lower scale
as the test process goes to avoid
possible damage to the ammeter and
the fuse.
Do not turn the main switch to "ON"
position during test.
If the leaked current exceeds the specified value,
it may indicate a short circuit.
Allowable current leakage: Less than 1 mA.
Disconnect each cable one by one and take
measurement of the current of each cable to
locate the short circuit.
white
REG.REC.
green/black
5
Auto
by-starter
5
16. ELECTRICAL EQUIPMENT
green
fuse(7A
)
red
red
Battery
12V 6AH
W
ground
wire
green
green
Battery(-) terminal