Charging System - Sym Fiddle 50 Service Manual

Hide thumbs Also See for Fiddle 50:
Table of Contents

Advertisement

Charging System

White
AC. Generator
Current Leakage Inspection
Turn the main switch to OFF position, and
remove the negative cable terminal (-) from the
battery.
Connect an ammeter between the negative cable
terminal and the battery negative terminal.
Caution
In the current leakage test, set the current
range at larger scale, then gradually
decrease to the lower scale as the test
process goes to avoid possible damage to
the ammeter and the fuse.
Do not turn the main switch to ON position
during test.
If the leaked current exceeds the specified value,
it may indicate a short circuit.
Allowable current leakage: Less than 1mA
Disconnect each cable one by one and take
measurement of the current of each cable to
locate the short circuit.
This chapter Contents
Green
Yellow
REG. REC.
Pink
Green/
Black
15. ELECTRICAL EQUIPMENT
Red
Battery
Ammeter
Ground circuit
Digital voltmeter
Fuse coupler
Battery (-) terminal
Ammeter
15-5