User Guide
Step 5 : Unlatch all of the connectors that attach the CMA(s) to the enclosure and the rail by locating
the latch release button and pressing it from either side of the latch. There are three total
connections that need to be removed, one at the elbow and two at the opposite end.
Step 6 : Grasp both handles at the front of the enclosure and pull with even pressure to extend the
chassis out of the rack until it is stopped by the safety latches. The safety latches will prevent the
enclosure from coming out of the rack completely and the cover will remain in the rack attached
to the rear alignment brackets.
Step 7 : Follow these steps to remove a Drive Assembly.
a. Find the latch release mechanism on the Drive Assembly being removed.
b. Insert a finger and a thumb into the latch release and pinch to unlatch the Drive Assembly.
Figure 68: Unlatching a CMA Connector
Figure 69: Chassis Handle Operation
4. Part Replacement