Toshiba e-STUDIO163 Service Manual page 209

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO163:
Table of Contents

Advertisement

4) Temperature control at Energy Saving Mode
This equipment has the following two types of temperature control for saving energy and returns to
ready status to perform printing in each mode upon printing request.
The period of time from the printing request to this mode can be set in Setting Mode (08).
Auto Power Save Mode (08-205):
When the printing is not performed in a specified period of time (default: 15 min.) after the previous
printing is completed, the equipment enters to Auto Power Save Mode to turn OFF the heater lamp.
* When a value other than OFF is set for the "Fuser roller temperature in Auto Power Save Mode
(code 08-409/448)", the equipment controls to maintain the fuser roller temperature at the preset
value by turning the 2 heater lamps ON/OFF alternately.
Auto Shut Off Mode (08-206):
When no operation is performed in a specified period of time (default: 15 min.) after the equipment
entered to Auto Power Save Mode, the equipment then enters Auto Shut Off Mode to be in the OFF
state (e.g. turns off the unnecessary displays on the control panel, etc.).
Warming-up
°C
170
Temperature
of fuser roller
Heater lamp
ON
0
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Ready
During printing
Fig. 13-4
13 - 7
Auto Power Save Mode
( Heater lamp OFF )
Fixed time ( 08-205 )
Fixed time ( 08-206 )
OFF
Auto
Shut Off
Mode
e-STUDIO163/203
FUSER / EXIT UNIT
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio203

Table of Contents