[G] Bypass sensor (S8)
(1)
Remove 1 screw on the bottom of the equip-
ment.
(2)
Take off the bypass sensor with the bracket.
(3)
Take off the actuator with the spring while
pushing the bracket stays wider.
(4)
Release 2 latches, take off the bypass sen-
sor, and disconnect the connector.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Bracket
Fig. 10-20
Spring
Fig. 10-21
Bracket
Bypass sensor
Fig. 10-22
10 - 15
Actuator
Bracket
Connector
e-STUDIO163/203
PAPER FEEDING SYSTEM