[F] CIS unit (CIS)
(1)
Take off the original glass.
P.6-12 "[A] Original glass"
(2)
Move the CIS unit to the right most position.
Notes:
Be sure to hold the CIS unit drive belt-1 to
move the CIS unit.
When the CIS unit is moved, be sure not
to touch the shaft as the silicon oil is
applied on it.
(3)
Remove the seal which fixes the harness.
Note:
Attach the seal by following the procedure
below.
-
Place the flat harness along the edge
of the scanner base.
-
Align the seal with the two edges of
the scanner base.
e-STUDIO163/203
SCANNER
Seal
Harness
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
6 - 16
06/04
CIS unit
Fig. 6-19
CIS unit drive belt-1
Fig. 6-20
Fig. 6-21