Displaying Power Usage Information - Cisco Nexus 9504 Hardware Installation Manual

Nx-os mode switch
Hide thumbs Also See for Nexus 9504:
Table of Contents

Advertisement

Displaying Power Usage Information

longer need the IP address. If you try to configure this unused IP address, you receive an error message that
prevents you from proceeding with the configuration. In this case, you need to enter the purge module 3
running-config command to clear the old configuration in Switch A before using the IP address.

Displaying Power Usage Information

To display the power usage information for the entire switch, use the show environment power command.
This command shows the power usage for the modules installed in the switch.
Power usage is reserved for both supervisor modules regardless of whether one or both supervisor modules
Note
are present.
Use the show environment power command to display power usage information for the switch.
switch# show environment power
Power Supply:
Voltage: 12 Volts
Power
Supply
-------
-
1
2
3
4
Module
-------
4
22
24
26
27
28
29
30
fan1
fan2
fan3
N/A - Per module power not available
Power Usage Summary:
--------------------
Power Supply redundancy mode (configured)
)
Power Supply redundancy mode (operational)
)
Total Power Capacity (based on configured mode)
Total Power of all Inputs (cumulative)
Total Power Output (actual draw)
Total Power Input (actual draw)
Total Power Allocated (budget)
Total Power Available for additional modules
switch#
Cisco Nexus 9504 NX-OS Mode Switch Hardware Installation Guide
48
Model
(Watts )
-------------------
----------
N9K-PAC-3000W-B
------------
------------
N9K-PAC-3000W
Model
-------------------
-----------
N9k-X9636PQ
N9K-C9504-FM
N9K-C9504-FM
N9K-C9504-FM
N9K-SUP-A
N9K-SUP-A
N9K-SC-A
N9K-SC-A
N9K-C9504-FAN
N9K-C9504-FAN
N9K-C9504-FAN
Actual
Actual
Output
Input
(Watts )
----------
----------
517 W
566 W
0 W
0 W
0 W
0 W
0 W
0 W
Actual
Power
Draw
Allocated
(Watts )
(Watts )
-----------
--------------
177.00 W
399.60 W
118.00 W
300.00 W
N/A
0.00 W
N/A
0.00 W
47.00 W
79.92 W
45.00 W
79.92 W
12.00 W
60.00 W
23.00 W
60.00 W
47 W
225.00 W
48 W
225.00 W
47 W
249.00 W
Managing the Switch
Total
Capacity
Status
(Watts )
-------------
3000 W
Ok
0 W
Absent
0 W
Absent
0 W
Shutdown
Status
Powered-Up
Powered-Up
Powered-Dn
Powered-Dn
Powered-Up
Powered-Up
Powered-Up
Powered-Up
Powered-Up
Powered-Up
Powered-Up
Non-Redundant(combined
Non-Redundant(combined
3000.00 W
3000.00 W
517.00 W
566.00 W
1728.24 W
1271.76 W