Displaying Power Usage Information; Reloading A Module - Cisco Nexus 7702 Hardware Installation Manual

Hide thumbs Also See for Nexus 7702:
Table of Contents

Advertisement

Managing the Switch
Scenario
A particular switching module is removed and the
same switching module is replaced before you enter
the copy running-config startup-config vdc-all
command again.
A particular switching module is removed and
replaced with the same type switching module, and
you entered the reload module slot_number
command.
A particular switching module is reloaded when you
enter the reload module slot_number command.

Displaying Power Usage Information

To display the power usage information for the entire switch, use the show environment power command.
This command shows the power usage for many of the modules installed in the switch. For the older modules
that do not have the capability to output this information, the output is shown as N/A.
Note
Power usage is reserved for both supervisor modules regardless of whether one or both supervisor modules
are present.
Enter the show environment power command.

Reloading a Module

You can reset a module by using the reload module command and specifying the module by its slot number
in the chassis.
Reloading a module disrupts traffic through the module.
Caution
Step 1
Enter the configure terminal command to enter the configuration terminal mode.
Displaying Power Usage Information
Consequence
The configured module information is preserved.
The configured module information is preserved.
The configured module information is preserved.
Cisco Nexus 7702 Hardware Installation Guide
47