Engineering Mode (T9300/T9400HRT/T9350/T9450HRT /T9500HRT)
Procedure
A. Setup model and unit
1. Put a safety Key on the console set. Press Elevation UP and Speed
Down Keys at the same time for five seconds. After you done, The dot
matrix will display"DGA3"and Time window display"ENG1"If yours is not
"ENG1".Press Elevation UP/DOWN or Speed Fast/Slow to let window
displays "ENG1"
2.
Press SELECT/SCAN Key once. Time Window will display "P0"
3.
Press Elevation UP Key through it displays
5.1
Version
4.
Press Fast/Slow key to choose model and unit in "X" window recording to Table A.
Then Press SELECT/SCAN to save data.
5.
Press Elevation Down through P0.Press Start.
6.
Use a tachmeter as a speed measure equipment and press Fast/Slow key until you
can measure minimum speed value (0.5M/1.0KM) by a tachmeter. Then press
SELECT/SCAN to save data.
7.
Press Elevation UP through P1.
8.
Press Start. Use a tachmeter as a speed measure equipment and press Fast/Slow
key until you can measure maximum speed value (10M/16Km or 19K) by a tachmeter.
Then press SELECT/SCAN to save data.
9.
Press Elevation UP through P5. Press Fast/Slow key until it reach the max incline
Then press SELECT/SCAN to save data
10. Press Elevation DOWN through P4. Press Fast/Slow key until it reach the min incline
Then press SELECT/SCAN to save data.
11. Remove Safety key and put on it again. You finish setup. By the way, if you need to
set up other parameters please reference Table.B