Error Message" E4" on the Console
Possible cause:
1. Range of elevation is too short.
2. PCB is damaged.
Fix:
1. Enter the engineering mode to re-calibrate the elevation.
2. Replace PCB.
Error Message " E5" on the Console
Possible cause:
1. Range of elevation is not proper.
2. PCB is damaged.
Fix:
2. Replace PCB
1. Enter the P4, P5 of
Engineering Mode1 to
recalibrate the incline.
If the elevation is stuck at
either end, release the
pipe before the
calibration.
7-9