Error Message "E6" on the Console
Possible cause:
1. 8-pin cable is damaged
2. 6-pin AMP plug of the elevation motor or 8-pin cable has not been
connected well
3. damaged PCB
4. damaged MCB
5. damaged elevation motor
Fix:
1. Replace the 8-pin cable.
2. Verify the connections of the 6-pin AMP plug of the elevation motor and
the 8-pin console cable.
3. Replace the PCB
4. Replace the MCB
5. Replace the elevation motor